My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HUNTER
>
642
>
2300 - Underground Storage Tank Program
>
PR0231148
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2024 3:13:00 PM
Creation date
5/13/2024 11:02:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231148
PE
2361
FACILITY_ID
FA0000799
FACILITY_NAME
Nashir Hunter Inc.
STREET_NUMBER
642
Direction
N
STREET_NAME
HUNTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13906035
CURRENT_STATUS
01
SITE_LOCATION
642 N HUNTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of CP22 - UST FULL violations that have not been <br /> addressed for Nashir Hunter Inc. as of July 11, 2024. <br /> Open violations from May 29, 2024 inspection <br /> Violation#30-2060015-Leak detection equipment located so leak is detected at the earliest possible <br /> opportunity(TCR 9d). <br /> OBSERVATION: The 87 sensor was raised approximately 7 inches off the lowest point of the sump and not located to <br /> detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. <br /> CORRECTIVE ACTION:The sensor was relocated to the lowest point of the sump by the service technician. Ensure <br /> that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#31 -2030062-Leak detection equipment has not been tampered with or disabled (TCR 9d). <br /> OBSERVATION: The 87 STP sump was observed with approximately 3.5 inches of liquid inside along with the sensor <br /> approximately 7 inches off the lowest point of the sump and not located to detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE:An operator of an underground storage tank system shall not allow tampering with or <br /> otherwise disabling automatic leak detection devices or alarms. <br /> CORRECTIVE ACTION: Immediately place the sensor at the lowest point of the sump and maintain the monitoring <br /> system in proper operating conditions at all times. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#53-2010007-Submitted/maintained current Cert of Financial Responsibility/mech of financial <br /> assurance(TCR 11). <br /> OBSERVATION: Current financial responsibility documents were not found on site. <br /> REGULATION GUIDANCE:A copy of current financial responsibility documents are required to be maintained on site. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site. <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.