Laserfiche WebLink
Environmental Health Department <br />CP22 - UST FULL Inspection Report <br />Date: <br />July 01, 2024 <br /> Facility Address: <br /> 1617 W FREMONT ST, STOCKTON <br /> Facility Name: <br /> ARCO 05450 <br /> □ OUT □ R □ COS2030051 - 0.1 gph piping test conducted on SW gravity systems every 24 mths and after piping <br />repair (TCR 9d) <br />CA Code of Regulations <br />2643(e), 2661(f) <br /> 17 <br /> □ OUT □ R □ COS2030029 - Tank lining inspected w /in 10 years of lining, every 5 years after, cert submitted to CUPA <br />(TCR 9c) <br />CA Code of Regulations <br />2663, 2712(b)(6) <br /> 18 <br /> □ OUT □ R □ COS2010005 - ELD testing results sent to the board and the CUPA within 60 days of completion of the <br />test <br />CA Code of Regulations <br />2644.1(a)(5) <br /> 19 <br /> □ OUT □ R □ COS2030056 - SIR Report submitted to the CUPA every 12 monthsCA Code of Regulations <br />2646.1(j) <br /> 20 <br /> □ OUT □ R □ COS2030064 - CUPA was notified within 48 hours prior to testingCA Code of Regulations <br />2637, 2638(e), 2643(g) <br /> 21 <br /> □ OUT □ R □ COS2030068 - Initial or triennial ELD testing conducted on UST system 1000’ of public wellCA Code of Regulations <br />2640(e), 2644.1 <br /> 22 <br /> □ OUT □ R □ COS2060001 - As-built plans for new installations and/or with the permit application have been <br />submitted <br />CA Code of Regulations <br />2635(e)(8) <br /> 23 <br /> □ OUT □ R □ COS2030003 - Leak detection system maintains continuous monitoring that activates an audible and <br />visual alarm <br />CA Code of Regulations <br />2632(c), 2634(d), <br />2636(f) <br /> 24 <br /> □ OUT □ R □ COS2030016 - Annular space of USTs are continuously monitored with an audible and visual alarm <br />system (TCR 9d) <br />CA Code of Regulations <br />2631(g), 2632(c)(2) <br /> 25 <br /> □ OUT □ R □ COS2030017 - Piping out of UDC is fail-safe/shut down, UDC leak shuts off pump/flow, or tightness <br />test (TCR 9d) <br />CA Code of Regulations <br />2636(f)(4) <br /> 26 <br /> □ OUT □ R □ COS2030018 - DW press piping is monitored with an audible/visual alarm or stops flow at UDC (TCR <br />9d) <br />CA Code of Regulations <br />2666(b)(2), 2636(f)(1) <br /> 27 <br /> □ OUT □ R □ COS2030043 - Leak detection equipment properly installed, calibrated, operated, and maintained (TCR <br />9d) <br />CA Code of Regulations <br />2638(a), 2641(j) <br /> 28 <br /> □ OUT □ R □ COS2060005 - UST system constructed with a mon system capable of detecting entry into secondary <br />containment <br />CA Health and Safety <br />Code 2636(a)(1), <br />25291(b) <br /> 29 <br /> □ OUT □ R □ COS2060015 - Leak detection equipment located so leak is detected at the earliest possible opportunity <br />(TCR 9d) <br />CA Code of Regulations <br />2630(d), 2641(a) <br /> 30 <br /> □ OUT □ R □ COS2030062 - Leak detection equipment has not been tampered with or disabled (TCR 9d)CA Health and Safety <br />Code 25299(a)(9) <br /> 31 <br /> □ OUT □ R □ COS2030075 - E Gen System LLD detects 3 gph leak & restricts/shuts off flow or activates aud /vis <br />alarm (TCR 9d) <br />CA Code of Regulations <br />2636(f), 2666(c), <br />2666(f) <br /> 32 <br /> □ OUT □ R □ COS2060022 - System has a mon system capable of detecting entry of haz sub or water into <br />secondary containment <br />CA Health and Safety <br />Code 25290.2(d) <br /> 33 <br /> □ OUT □ R □ COS2030034 - Tag/sticker on affixed monitoring equipment being certified, repaired, or replacedCA Code of Regulations <br />2638(f), 2641(j) <br /> 34 <br /> □ OUT □ R □ COS2030065 - Interstitial space of the UST is under constant VPH monitoring (TCR 9d)CA Health and Safety <br />Code 25290.1(e) <br /> 35 <br /> □ OUT □ R □ COS2060023 - System has a mon system that can detect entry of haz sub liquid/vapor, or water into <br />sec contain <br />CA Health and Safety <br />Code 25290.1(d) <br /> 36 <br /> □ OUT □ R □ COS2030009 - Cathodic protection is installed/maintained as required, including required documentation <br />(TCR 9c) <br />CA Code of Regulations <br />2635, 2636(b), 2662, <br />2712 <br /> 37 <br /> □ OUT □ R □ COS2030005 - SW tank continuous in tank leak detection test is functioning properly (TCR 9d)CA Code of Regulations <br />2643(b)(3) <br /> 38 <br /> □ OUT □ R □ COS2030006 - Monthly 0.2 gph ATG test is being conducted and copies of test results are available <br />(TCR 9d) <br />CA Code of Regulations <br />2643(b)(1) <br /> 39 <br /> □ OUT □ R □ COS2060002 - SW UST system has monitoring system capable of detecting releases (TCR 9d)CA Health and Safety <br />Code <br /> 40 <br />FA0003606 PR0231923 SC001 07/01/2024 <br />EHD Rev. 12/06/2021 CP22 - UST FULL OIRPage 2 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD