Laserfiche WebLink
J <br /> Environmental Health Department <br /> A N0 A 0 U I N <br /> t� : -�'o-- C:0U N TY <br /> Y � + Greatness grows Frere. <br /> Swimming Pool Official Inspection Report <br /> Name of Facility:ECONOLODGE INN AND SUITES Date: 06/03/2024 <br /> Address: 118 N CHEROKEE LN, LODI 95240 <br /> Owner/Operator: ECONOLODGE INN AND SUITES Telephone: (415)490-8233 <br /> Program Element: 3611 - PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: Routine Reinspection on or after: <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public <br /> health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #10 Disinfectant Residual MAJC <br /> OBSERVATIONS:The free residual chlorine was observed at 0.6 ppm. Maintain the free residual chlorine levels between 2.0 <br /> ppm and 10 ppm. Pool is CLOSED due to low free residual chlorine levels. Chargeable re inspection required prior to re opening <br /> pool. <br /> CALCODE DESCRIPTION:Public pools,when open or in use,shall be disinfected continuously by approved chemicals and shall <br /> maintain the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid,2.0 ppm to 10.0 ppm free chlorine with <br /> cyanuric acid or 2.0 ppm bromine. Spas,wading pools,and spray grounds shall maintain the following concentrations:3.0 ppm to <br /> 10.0 ppm free chlorine or 4.0 ppm bromine. (CCR 65529) <br /> This is(Major)Violation. <br /> #3 Safety Signs <br /> OBSERVATIONS:Observed safety signs are destroyed and faded. Obtain new signs with legible information. Correct within 7 <br /> days. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained.(CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high,unless otherwise specified.Safety signs shall be affixed to a wall, pole,gate,or similar <br /> permanent structure in a location visible to all pool users,unless otherwise specified.(CBC 3120B) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The hand rails in the deep end of pool are loose. Secure and tighten hand rails. Correct today. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a <br /> point above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck.(CBC 3111 B) <br /> Pool operator shall keep ladders and handrails well maintained.(CCR 65535) <br /> PR0360644 06/03/2024 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />