Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East HazeIton Avenue, Stockton, CA 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sigiov.org/ehd <br />Swimming Pool Official Inspection Report <br />Time In. 12 -00 pm <br />Time Out: 1:00 pm <br />Name of Facility: VENETIAN GARDEN HOA REC CENTER Date: 08/16/2017 <br />Address: 1555 MOSAIC WAY,STOCKTON 95207 <br />Owner/Operator: VENETIAN GARDENS ASSOC Telephone: (209) 477-3871 <br />Program Element: 3611 - PUBLIC POOL/SPA- PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#9 Ladders and Handrails <br />OBSERVATIONS: Loose handrails. Tighten loose handrails within two weeks. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />#10 Disinfectant Residual <br />OBSERVATIONS: Low level of free chlorine. Provided acceptable range between 2ppm and 10ppm <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br />#35 Flow Meters <br />OBSERVATIONS: Flow meter. Provide a functional flow meter. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />#36 Pressure and Vacuum Gauges <br />OBSERVATIONS: Effluent gauge. Provide an effluent gauge within one month <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate: <br />Cyanuric acid: <30 ppm pH: 7.4 Combined chlorine: 00.00 ppm <br />NOTES <br />FA0001674 PRO360166 SC001 08/16/2017 <br />80 gpm Chlorine: 1.2 ppm Temp: ° F <br />EHD 36-01 Rev. 06/30/15 Page 1 of 2 <br /> Swimming Pool OIR