Laserfiche WebLink
SAN JOAQUIN <br /> Environmental Health Department <br />Time In: 10.15 am <br />Time Out: 1045 am <br />Swimming Pool Official Inspection Report <br />Name of Facility: MOTEL SIX Date 07/08/2020 <br />Address: 150 NORTHWOODS AVE, MANTECA 95336 <br />Owner/Operator: TRIDEVI INC Telephone (209) 239-5900 <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Inspection Type: INSPECTION/REINSPECTION (Chargeable) Reinspection on or after: 07/15/2020 <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#12 pH Level MAJOR <br />OBSERVATIONS: pH is >8. Provide pH 7.2 - 7.8 today. <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: Light and GFCI are not functional. As per Manager, they will not use the light fixtures for now. Post" NO <br />SWIMMING AFTER DARK" sign before reopening. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />#9 Ladders and Handrails <br />OBSERVATIONS: Single and double hand rails are loose. Fix before reopening. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: gpm Chlorine: 8.6 ppm <br /> <br />Cyanuric acid: ppm pH: >8 Combined chlorine: <br />NOTES <br />Pool re inspection. <br />Free chlorine is within the codes range. <br />Pool will be kept CLOSED due to high pH. <br />Re inspection is required in 1 week. <br />FA0000959 PR0360398 SC333 07/08/2020 <br />iD 36-01 Rev. 06/30/15 <br /> Page 1 of 2 Swimming Pool OIR <br />Temp: ° F <br />ppm <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com