COMPLIANCE INFO_PRE-2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NORTHWOODS
>
150
>
3600 - Recreational Health Program
>
PR0501227
>
COMPLIANCE INFO_PRE-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2024 1:13:35 PM
Creation date
6/17/2024 1:11:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE-2020
RECORD_ID
PR0501227
PE
3612
FACILITY_ID
FA0000959
FACILITY_NAME
MOTEL SIX
STREET_NUMBER
150
STREET_NAME
NORTHWOODS
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20830004
CURRENT_STATUS
01
SITE_LOCATION
150 NORTHWOODS AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br /> Environmental Health Department <br />i .1 i • • <br />` <br />—C OU N T Y— <br />Greatness grows hro <br />Swimming Pool Official Inspection Report <br />Time In 11•06 am <br />Time Out: 11:40 am <br /> <br />Name of Facility: MOTEL SIX Date: 06/09/2020 <br />Address: 150 NORTHWOODS AVE, MANTECA 95336 <br />Owner/Operator: TRIDEVI INC Telephone (209) 239-5900 <br />Program Element: 3612- PUBLIC POOL/SPA - ADDITIONAL <br />Inspection Type: ROUTINE INSPECTION - Operating Permit l'e• i ‘,/ r c . r.d <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is 1.6ppm. Provide free chlorine 3ppm - 1Oppm today. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br />#25 Spa Emergency Shut Off Switch <br /> MAJOR <br />OBSERVATIONS: Emergency shut off switch is not functioning properly with very weak water jets. Repair and install ideal <br />shut off switch to the spa in 2 weeks. <br />CALCODE DESCRIPTION: A clearly labeled emergency shut off switch for both the spa recirculation and jet/aeration systems shall be <br />installed adjacent to the spa pool. (CBC 3138B) <br />#3 Safety Signs <br />OBSERVATIONS: "Keep gate closed" sign and active diarrhea sign are not posted to the accessing gates. Post signs in 1 <br />week. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br />#9 Ladders and Handrails <br />OBSERVATIONS: Double hand rail is loose. Fix in 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />FA0000959 PR0501227 SC001 06/09/2020 <br />EHD 36-01 Rev. 06/30/15 Page 1 of 3 Swimming Pool OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.