Laserfiche WebLink
SAN ,JOAQUIN <br />Cou NT <br />Environmental Health Department <br />Time In: 9.15 am <br />Time Out 9:55 am <br />Swimming Pool Official Inspection Report <br />Name of Facility: BEECHWOOD COMMON COA Date: 08/31/2018 <br />Address: 328 NORTHBANK CT, STOCKTON 95207 <br />Owner/Operator: BEECHWOOD COMMON CONDO ASSN Telephone: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY &de atLiz. / 3,2 4/6 <br />Inspection Type: INSPECTION/REINSPECTION (Chargeable) <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#7 Pool Deck <br />OBSERVATIONS: There are gaps between coping stones and deck. Fill in by April 2019 <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: Light turned on and GFI shut it off. Then it was impossible to turn light back on. Replace GFI by 1 week. <br />Make sure light works. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />#18 Pool Shell and Tile <br />OBSERVATIONS: Several tiles are missing. Replace by April 2019 <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Per pool service skimmers have major leaks and is causing the water level to always be low. Repair all <br />leaks, immediately for proper circulation of water. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: gpm Chlorine: 3.2 ppm Temp: ° F <br /> <br />Cyanuric acid: ppm pH: 7.6 Combined chlorine: ppm <br />FA0001892 PR0360008 S0333 08/31/2018 <br />El-ID 36-01 Rev. 06/30/15 Page 1 of 2 Swimming Pool OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com