Laserfiche WebLink
Time In 1045 am <br />Time Out: 11:24 am <br />San Joaquin County <br />Environmental Health Department <br />1868 East HazeIton Avenue, Stockton, CA 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: vvww.sjgov.org/ehd <br />Swimming Pool Official Inspection Report <br />Name of Facility: MG WATERSTONE APARTMENTS LP Date: 07/14/2015 <br />Address: 1951 W MIDDLEFIELD DR, TRACY 95377 <br />Owner/Operator: MG WATERSTONE APARTMENTS LP Telephone: (209) 830-1580 <br />Program Element: 3612- PUBLIC POOL/SPA-ADDITIONAL <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine at 1.2ppm. Maintain free chlorine between 3.0-10.0ppm. Corrected to 2.4ppm. <br />VIOLATION DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall <br />maintain the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with <br />cyanuric acid or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 <br />ppm free chlorine or 4.0 ppm bromine. (CCR 65529) <br />#22 Skimmer Assembly <br />OBSERVATIONS: 2 Weirs lacking and one float valve assembly lacks check valve. Provide in 2 weeks. <br />VIOLATION DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />#36 Pressure and Vacuum Gauges <br />OBSERVATIONS: Effluent gauge is lacking. Re-install in 2 weeks. (new piping installed) <br />VIOLATION DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: 120 gpm Chlorine: 1.2 ppm Temp: 100.00 ° F <br /> <br />Cyanuric acid: 50 ppm pH: 7.4 Combined chlorine: 0.4 ppm <br />NOTES <br />Inf-16psi, Eff-? <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: <br /> <br />Name and Title: Melissa, Property Manager <br /> <br />EH Specialist: MELISSA NISSIM Phone: (209) 468-3168 <br />FA0017844 PR0526368 SC001 07/14/2015 <br />Page 1 of 1 Swimming Pool OIR EH D Rev. 06/30/15