COMPLIANCE INFO_PRE 2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NIKKEL
>
1360
>
3600 - Recreational Health Program
>
PR0528986
>
COMPLIANCE INFO_PRE 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2024 1:23:10 PM
Creation date
6/20/2024 1:22:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2020
RECORD_ID
PR0528986
PE
3611
FACILITY_ID
FA0019393
FACILITY_NAME
BETHANY HOME
STREET_NUMBER
1360
STREET_NAME
NIKKEL
STREET_TYPE
WAY
City
RIPON
Zip
95366
CURRENT_STATUS
01
SITE_LOCATION
1360 NIKKEL WAY
P_LOCATION
05
P_DISTRICT
000
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Filter Cleaning and Maintenance 'f c A 1 <br />San Joaquin County <br />Environmental Health Department <br />1868 East HazeIton Avenue, Stockton, CA95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sjgov.org/ehd <br />Swimming Pool Official Inspection Report <br />Facility Name and Address: BETHANY HOME, 1360 NIKKEL WAY, RIPON 95366 <br />#35 Flow Meters <br />OBSERVATIONS: The flowmeter for the south pump is not functioning. Repair/replace by 1 week. <br />VIOLATION DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />W$ Flow Meters V LA C PTE <br />OBSERVATIONS: The flowmeter for the south pump is not functioning. Repair/replace by 1 week. <br />VIOLATION DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />#38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The filters may need to be backwashed. The pressure of the water coming off of the filters is greater <br />than the pressure of the water going in. <br />VIOLATION DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OBSERVATIONS: The filters may need to be backwashed. The pressure of the water coming off of the filters is greater <br />than the pressure of the water going in. <br />VIOLATION DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: 100 gpm Chlorine: 6.4 ppm Temp ° F <br /> <br />Cyanuric acid: <30 ppm pH: 7.6 Combined chlorine: 0.4 ppm <br />NOTES <br />Influent 19/25 Effluent 21/55 Flow meters 0/100 <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: <br /> <br />Name and Title: Larry, <br /> <br />EH Specialist: KADEANNE LINHARES Phone: (209) 468-0330 <br />FA0019393 PR0528986 SC001 08/04/2015 <br />Page 2 of 2 Swimming Pool OIR END 36-01 Rev, 06/30/15