My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNPIKE
>
3504
>
4400 - Solid Waste Program
>
PR0515730
>
CORRESPONDENCE_2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2024 3:15:47 PM
Creation date
6/27/2024 2:23:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2006
RECORD_ID
PR0515730
PE
4430 - SOLID WASTE CIA SITE
FACILITY_ID
FA0012310
FACILITY_NAME
WORLD ENTERPRISES
STREET_NUMBER
3504
Direction
S
STREET_NAME
TURNPIKE
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17517018
CURRENT_STATUS
Active, billable
SITE_LOCATION
S TURNPIKE RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
3504 S TURNPIKE RD STOCKTON 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
285
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LABORATORY NARRATIVE <br /> Modified ASTM D-1946 <br /> URS Corporation <br /> Workorder#0512184B <br /> Two 6 Liter Summa Canister samples were received on December 07, 2005. The laboratory performed <br /> analysis via Modified ASTM Method D-1946 for Methane and fixed gases in air using GC/FID or <br /> GC/TCD. The method involves direct injection of 1.0 mL of sample. <br /> On the analytical column employed for this analysis,Oxygen coelutes with Argon. The corresponding peak is <br /> quantitated as Oxygen. <br /> Since Nitrogen is used to pressurize samples, the reported Nitrogen values are calculated by adding all the <br /> sample components and subtracting from 100%. <br /> Method modifications taken to nm these samples include: <br /> Requirement ASTMD-1946 ATL Modifications <br /> Calibration A single point A 3-point calibration curve is performed.Quantitation is <br /> calibration is performed based on a daily calibration standard which may or may <br /> using a reference not resemble the composition of the associated samples. <br /> standard closely <br /> matching the <br /> composition of the <br /> unknown. <br /> Reference Standard The composition of any The standards used by ATL are blended to a>/=95% <br /> reference standard accuracy. <br /> must be known to <br /> within 0.01 mol%for <br /> any component. <br /> Sample Injection Volume Components whose The sample container is connected directly to a fixed <br /> concentrations are in volume sample loop of 1.0 mL on the GC. Linear range is <br /> excess of 5%should defined by the calibration curve.Bags are loaded by <br /> not be analyzed by vacuum. <br /> using sample volumes <br /> greater than 0.5 mL. <br /> Normalization Normalize the mole Results are not normalized. The sum of the reported <br /> percent values by values can differ from 100%by as much as 15%,either due <br /> multiplying each value to analytical variability or an unusual sample matrix. <br /> by 100 and dividing by <br /> the sum of the original <br /> values.The sum of the <br /> original values should <br /> not differ from 100%by <br /> more than 1.0%. <br /> Precision Precision requirements Duplicates should agree within 30%RPD for detections> <br /> established at each 5 X's the RL. <br /> concentration level. <br /> Page 2 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.