Laserfiche WebLink
Thanks for taking a few minutes to discuss the comments with me this afternoon. <br /> The responses to the review comments are below in RED. <br /> No revisions to the plans have been made per this set of review comments. I have attached the set of plans dated 2024- <br /> 04-05 for your convenience. <br /> Please let me know if you have any questions.Thanks, <br /> Alex Korek <br /> Diamond Z Engineering, Inc. <br /> 5670 State Road-Cleveland,OH 44134 <br /> (440) 842-6501 (Office) <br /> (440) 596-8523 (Cell) <br /> From: Saetern, Kristina Gaen [EHD] <ksaetern@s4gov.org> <br /> Sent:Thursday,April 18, 2024 11:23 AM <br /> To: s.mann@norcaloffice.com; Alex Korek<Alex.Korek@dia mondzengineering.com> <br /> Cc:Gurkamal Dhaliwal<g.dhaliwal@norcaloffice.com>; 'CJ Dhaliwal' <ca.dhaliwal@norcaloffice.com> <br /> Subject: SR0083837-4607 Airport Way <br /> Hello, <br /> The San Joaquin County Environmental.HeaLth Department(EHD) has completed a preLiminary review of the <br /> underground storage tank instal.Lation application for 4607 Airport Way, Stockton (SR0083837). PLease provide the <br /> following additional information and address the following comments: <br /> 1. Clarify the following: Franklin Fueling flex connectors model numbers on the part list(FIVI-2) does not match the <br /> cut sheet provided. Provide cut-sheets with the model numbers. <br /> Per our conversation 4/24/2024, this comment has been resolved since Franklin Fueling does not offer a cut- <br /> sheet for every flex connector option. <br /> 2. Provide the OPW drop tube cut sheet for 71SO-410C.This was changed from 71SO-410CB. <br /> See attached. <br /> 3. What is the ground water/water table level? <br /> The ground water is approximately 50' below grade. <br /> 4. Identify and provide septic and well locations on the site plan. <br /> The site has public water and sewer and does NOT contain a septic or a well. <br /> 5. Clarify the single wall fiberglass information on page CS-1 Section 9 Vent Piping Installation. Per the installation <br /> guide, it mentions single wall installation for vent piping. Be specific. <br /> The site has both double wall vent piping and single wall vent piping.The only single wall vent piping is for DEF. <br /> The gasoline, diesel, and B20 will have double wall vent piping. <br /> CS-1 Section 9 Vent Piping Installation, paragraph 5 specifies the Double Wall vent piping. California Variant: <br /> Vent piping to be double walled and installed with continuous vacuum monitoring device per AB-2481 <br /> requirements. <br /> 8 <br />