Laserfiche WebLink
DocuSign Envelope ID: 618BCOD1-3A2D-412B-BA33-27E602E49359 <br /> SA N J O A Q U I N Environmental Health Department <br /> --- C O U N T Y--- <br /> F. SYSTEM PIPING CONTINUED: <br /> Check Code <br /> Box Section <br /> HSC Piping compatible with material intended to be stored. <br /> 25290.10M <br /> 25290.2 <br /> 23 CCR <br /> / 2631(b) Design and construction of piping approved by independent testing organization (e.g. UL). <br /> Piping, including vent lines, sloped toward tank(s) with minimum 1/8 inch slope per 1 foot of run. <br /> HSC <br /> 25290.1 k Vapor recovery, fill riser, and vent line piping are secondarily contained. <br /> 25290.2�c�&Q> <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check Code <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> M 2635(b) Manufacturer OPW Model 6571 EVRB-164042RT052 for Regular and Premium Gasoline <br /> 6571 EVRL-164042RT051 for 1320, Diesel, and DEF <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer OPW Model 71SO-410C <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> Fiberglass reinforced plastic (FRP) <br /> / Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> 26 5 CCR <br /> 2 ❑ Steel tank with field installed cathodic protection or impressed <br /> / current <br /> Tie-downs, when used, constructed of non-corrosive material or coated steel. <br /> 7 of 8 <br />