Laserfiche WebLink
VEEDER-ROOT F"IF Single-Point Mini-Hydrostatic Sensor for <br /> OF V Double-Wall Sumps Specifications <br /> Sensor Description Single-Point Min i-Hydrostatic The Single-Point Mini-Hydrostatic Sensor accurately detects fluid level change in the interstice <br /> reservoir of a double-wall sump.If a leak occurs in the sump interstice,the brine seeps out of the <br /> Sensor for Double-Wall Sumps reservoir triggering a low level alarm. <br /> Part Number 794380-304 <br /> L Discriminating Level Sensing <br /> Category [:] Non-Discriminating Static Testing <br /> F1 Position Sensitive Hydrostatic <br /> [vl Gas E-1 5 Green Diesel <br /> F/I Diesel E-85 DEF <br /> Fuel Compatibility FYI Kerosene Z E-1 00 Z Waste Oil <br /> Jet Fuel [V] Bio-Diesel 20 Motor Oil <br /> Aviation Gas [V] Bio-Diesel 100 <br /> Console Compatibility Recommended Sensor Interface Modules <br /> (*International Onlyl) Min.Console Module Part# Module Description of Modules per Console of Sensor Availability <br /> Software Inputs per Module <br /> TLS-450PLUS(8600 Series) 6A or Higher Universal Sensor Up to 4-TLS-4XX <br /> 332812-001 Up to 8-TLS-4XX 16 Sold Separately <br /> TLS-450 4A or Higher Module(USM) w/opt.TLS-XB <br /> TLS4(8601 Series)1 330020-750 12 <br /> TLS4i(8601 Series) 6A or Higher Universal Sensor Input 1 Included <br /> TLS413(8601 Series)1 Out-put Module <br /> 330020-751 (USIOM-AC) 6 <br /> TLS4c(8601 Series) <br /> TLS-350/R/PLUS 329958-001 Interstitial Sensor Up to 8 8 Sold Separately <br /> Interface Module <br /> TLS-350J 329356-003 4 Probe/4 Sensor 4 Sold Separately <br /> 124/324 or Higher Interface Module <br /> TLS-300i 330230-001 4 Probe/8 Sensor 1 <br /> Interface Module 8 Included <br /> TLS-300C 330513-001 2 Probe/8 Sensor Options <br /> Normal Float is in UP position(correct amount of brine in reservoir) <br /> Alarm Notification Fuel Alarm Float is in DOWN position(low brine level in reservoir) <br /> Sensor Out Sensor not communicating to ATG/Console <br /> Specifications Example Installati.r <br /> Operating Principle Reed Switch/Float <br /> Product Activation Height 0.79"(2cm) <br /> Operating Temperature -13 to+1 22'F(-25 to+50'C) <br /> Concrete <br /> Dimensions 2.5"(6.4cm)high,1.5"(3.8cm)dia. pact, <br /> Standard Cable Length:8ft(2.43m); Double-wall sump <br /> Miscellaneous/Notes up to 50%ethylene glycol in water;up Sensor in interstitial fluid reservoir <br /> to 50%propylene glycol in water,salt Coupling and seals as <br /> brine solution of up to 30%CaCl. required for conduit <br /> egress(customer <br /> TLS-3XXITLS-450 Series Consoles supplied) Seal-off and junction box <br /> Third Party Evaluation Links TLS4(8601 Series)Consoles (customer supplied) <br /> Product Link Single-Point Mini-Hydrostatic Sensor Rigid conduit to console Use tie wraps to <br /> keep cable clear of <br /> Warranty with System 1 Yr Parts&Labor sum components <br /> and rid <br /> Warranty(When <br /> purchased separately) 1 Yr Parts Only Tan_� <br /> Where Used(Typical) El ConvaultTank 77 <br /> [7] Dispenser Pan F/I AnnularSpace 77T <br /> F-1 Spill Containment F1 Monitoring Well <br /> F-1 STP Sump Oil/Water Separator Tank <br /> www.veeder.com 125 Powder Forest Drive-PO Box 2003-Simsbury,CT 06070-02019 Veeder-Root-P/N 577013-750-20 Rev.AD <br /> 1.888.561.7942 All information contained in this document is subject to change without notice. <br />