SAN JOA UIN <br />COUNT <br />G'rratrress grows here, <br />Environmental Health Department <br />Service Request Inspection Report <br />Name of Facility: ARCO <br />Date: 12/10/2025 <br />Address: 4607 S AIRPORT WAY, STOCKTON 95206 <br />Requestor: <br />Telephone: () - <br />Program Element: 2303 - UST/PIPING INSTALLATION <br />Request #: SR0083837 <br />Inspection Type: 131 - UST INSTALLATION INSPECTION <br />Onsite Service Technician: Ryan Frederickson <br />ICC Service Tech/Installer Exp. Date: 12/03/2026 <br />Manufacturer training: VR, 12/02/26; VMI, 11/22/26 <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />-Reviewed vacuum zone volume programming - not accurate. <br />-Witnessed leak detector testing of all 4 leak detectors. Passed. <br />-Reviewed leak detector line length programming - not accurate. <br />-Witnessed monitoring system functionality testing. All passed. <br />Notes: <br />-The 208 sensor in the 15/16 UDC was replaced during the inspection. The new sensor was tested and passed. <br />-Multiple tank top sump gaskets were observed to be either missing or improperly installed and liquid was observed in the sumps. <br />All tank top sumps, including vent sumps, are required to be liquid and vapor tight. Reinstall appropriate manufacturer gaskets. <br />-Adhesive observed on several sump electrical penetrations was not the color of the Bravo and NOV adhesive used on other <br />penetrations. The penetrations were a pale cream color. Provide manufacturer information and approval for this adhesive. <br />-1320 was not observed on site. The tank approved for storage of B20 was labeled as Renewable Diesel. Update CERS with <br />accurate storage information. <br />-The panel contained inaccurate PLLD line length information and inaccurate vacuum sensor zone volume information. An updated <br />system setup was provided at the end of inspection. This information will need to be reviewed and verified as accurate by EHD. <br />The facility is approved to receive fuel. <br />The facility is NOT approved to operate. <br />Additional inspections are required. Refer to the approval letter dated June 14, 2024, for a full list of outstanding requirements. <br />Please submit inspection requests in writing to UST@sjgov.org with 48 hours advance notice. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: <br />EH Specialist <br />LYNSEY SAMMONS <br />Name and Title: Emailed to CJ Dhaliwal. Owner <br />Phone: (209) 616-3067 <br />EHD Rev.09/16/2020 <br />FA0024830 SR0083837 SC131 12/10/2025 <br />Page 1 of 1 Service Request Inspection Report <br />