Laserfiche WebLink
J <br /> Environmental Health Department <br /> A N 0 A 0 U I N <br /> t� : -�'o-- C:0U N TY <br /> Y � + Greatness grows Frere. <br /> Swimming Pool Official Inspection Report <br /> Name of Facility:ORCHARD ESTATE MOBILE HOME PARK Date: 06/24/2024 <br /> Address: 812 CLOVER RD,TRACY 95376 <br /> Owner/Operator: ORCHARD ESTATE MOBILE HOME PARK Telephone: ()- <br /> Program Element: 3611 - PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: Routine Reinspection on or after: <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public <br /> health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #2 Pool Enclosure <br /> OBSERVATIONS:Part of the pool enclosure fencing (west side of pool room)is deteriorating at the bottom making the pool <br /> fencing loose. Repair/replace by 1 month. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence, portion of a building,wall,or other <br /> approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere. Doors,openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. <br /> (CBC 31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum <br /> effective perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members <br /> shall be spaced at least 48 inches apart.No planters or other climbable structures shall be permitted within 5 feet of the pool <br /> enclosure or within a 5-foot arc.Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool <br /> enclosures with a height of 4 or more feet are allowed if the enclosure was constructed prior to July 1994. (CBC 311913) <br /> This is(Minor-Food)Violation. <br /> #3 Safety Signs <br /> OBSERVATIONS:The pool enclosure entrance gate lacks a"Keep Gate Closed"sign. Post a Keep Gate Closed sign on the <br /> exterior side of the pool enclosure entrance gate. Correct by 1 week. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained.(CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high,unless otherwise specified.Safety signs shall be affixed to a wall, pole,gate,or similar <br /> permanent structure in a location visible to all pool users,unless otherwise specified.(CBC 312013) <br /> This is(Minor-Food)Violation. <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Both skimmers lack weir doors. Install properly fitting weir doors at both skimmers by 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall <br /> be maintained in accordance with manufacturer specifications.(CBC 313613) <br /> This is(Minor-Food)Violation. <br /> PR0360416 06/24/2024 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />