Environmental Health Department <br />Telephone: () - Owner/Operator: COLLECTIVE COMMUNITY ASSOCIATION <br />Inspection Type: Routine <br />Address: 1295 PARKCREST CIR, MANTECA 95336 <br />Date: 06/20/2024Name of Facility:COLLECTIVE COMMUNITY ASSOCIATION <br />Reinspection on or after: <br />Swimming Pool Official Inspection Report <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public <br />health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />VIOLATIONS AND CORRECTIVE ACTIONS <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: One of four light fixtures is burned. Replace light fixture in 2 weeks. As per Property Manager, there is a <br />order placed for new one. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of <br />the pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck <br />lighting is not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and <br />shall secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The difference between the Influent and Effluent pressure is more than 10 PSI at one of pumps. Back wash/ <br />clean filter today. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure <br />gauge located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves <br />so that it can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />Combined chlorine:ppm7.8 <br />3.2 <br /><30 <br />150 <br />NOTES <br />Pool inspection. <br />Influent 22 PSI <br />Effluent 11 PSI <br />Light fixtures and GFCI are working. <br />Kit and maintained log are on site. <br />Body hook and life ring on site. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0545807 06/20/2024 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD