My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
2800 - Aboveground Petroleum Storage Program
>
PR0515721
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2024 10:48:58 AM
Creation date
7/30/2024 12:51:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0515721
PE
2832
FACILITY_ID
FA0007101
FACILITY_NAME
FORWARD INC LANDFILL
STREET_NUMBER
9999
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106003
CURRENT_STATUS
01
SITE_LOCATION
9999 S AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> CQLJIVTY AMENDED <br /> 6/26/2024 <br /> CP22 - AST Non-Qualified Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FORWARD INC LANDFILL 9999 S AUSTIN RD, MANTECA June 21 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> diked areas. Submit proof of correction to the EHD. <br /> This is (Minor)Violation. <br /> 57 Code of Fed Regulations 112.7(e), 112.8(c)(6)4010021 -Written Inspection/testing procedures kept, inspection/testing <br /> records signed, kept for 3 years. <br /> OBSERVATION:The facility failed to keep written procedures and records of inspections and tests, including integrity <br /> tests,for at least three years. Copies of inspection and testing records for before 2023 were not found on site. <br /> REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with written <br /> procedures that you or the certifying engineer develop for the facility. You must keep these written procedures and a <br /> record of the inspections and tests, signed by the appropriate supervisor or inspector,with the SPCC Plan for a period <br /> of three years. Records of inspections and tests kept under usual and customary business practices will suffice for <br /> purposes of this paragraph. 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular schedule <br /> and whenever you make material repairs. <br /> CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br /> developed in the Spill Prevention, Control, and Countermeasure(SPCC)Plan. Records of these inspections and tests <br /> must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. <br /> Immediately locate a copy of all inspection and testing records for the last three years, maintain them on-site, and <br /> submit copies to the EHD. <br /> This is (Minor)Violation. <br /> 74 CA Health and Safety Code 25270.6(a)4010032-Tank Facility Statement or Business Plan has been submitted. <br /> OBSERVATION:An accurate business plan has not been submitted. <br /> -The inventory provided in CERS inaccurately indicates that the mobile fuel truck holds 11,000 gallons of Diesel. Per <br /> Osvaldo Cordero,the mobile fuel truck holds at most 250 gallons of Diesel. <br /> REGULATION GUIDANCE: (a)(1)On or before January 15, annually, each owner or operator of a tank facility subject <br /> to this chapter shall file with the statewide information management system, a tank facility statement that shall <br /> identify the name and address of the tank facility, a contact person for the tank facility,the total storage capacity of <br /> the tank facility, and the location and contents of each petroleum storage tank that exceeds 10,000 gallons in storage <br /> capacity. A copy of a statement submitted previously pursuant to this section may be submitted in lieu of a new tank <br /> facility statement if no new or used storage tanks have been added to the facility or if no significant modifications have <br /> been made. For purposes of this section, a significant modification includes, but is not limited to, altering existing <br /> storage tanks or changing spill prevention or containment methods. (2) Notwithstanding paragraph (1), an owner or <br /> operator of a tank facility that submits a business plan, as defined in subdivision (d)of Section 25501 ,to the <br /> statewide information management system and that complies with Sections 25503 , 25505 , 25505.1 , 25507 , <br /> 25507.2 , 25508 , 25508.1 , and 25508.2 , satisfies the requirement in paragraph (1)to file a tank facility statement. <br /> CORRECTIVE ACTION: Immediately submit a complete and adequate tank facility statement or a business plan. <br /> Submit proof of correction to the EHD. <br /> This is(Minor)Violation. <br /> 79 CA Health and Safety Code 25404(e)(4)4010-Administration/Documentation-General. <br /> FA0007101 PR0515721 SCO01 06/21/2024 <br /> EHD Rev.12/06/2021 Page 6 of 7 CP22-AST Non-Qualified OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.