COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1945
>
2800 - Aboveground Petroleum Storage Program
>
PR0516365
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2024 10:49:11 AM
Creation date
7/30/2024 2:10:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0516365
PE
2832
FACILITY_ID
FA0009397
FACILITY_NAME
CALPORTLAND COMPANY - LATHROP READY MIX
STREET_NUMBER
1945
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19803011
CURRENT_STATUS
01
SITE_LOCATION
1945 LATHROP RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - AST Non-Qualified Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CALPORTLAND COMPANY- LATHROP READY 1945 LATHROP RD LATHROP June 21 2024 <br /> 86 4045-Release/Leaks/Spills-General Local Ordinance ❑OUT ❑R ❑COS <br /> 87 See below 4050-Abandonment/Illegal Disposal/Unauthorized Treatment-General ❑OUT ❑R ❑COS <br /> 88 4055-Abandon menUlllegal Disposal/Unauthorized Treatment-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 3 Code of Fed Regulations 112.3 4030038-SPCC has been implemented. <br /> OBSERVATION:The Spill Prevention, Control, and Countermeasure(SPCC)Plan was not implemented, as required. <br /> -SPCC plan mentioned the site has overfill prevention in the form of a liquid gauge but it was not found on site. <br /> -SPCC plan mentioned that the secondary containment has a drain but according to Anthony Fuentes the secondary <br /> containment does not have a drain. <br /> REGULATION GUIDANCE: 112.3: The owner or operator or an onshore or offshore facility subject to this section must <br /> prepare in writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter"SPCC Plan"or <br /> "Plan")," in accordance with § 112.7 and any other applicable section. 25270.4.5.(a):An owner or operator shall <br /> conduct periodic inspections of the storage tank to ensure compliance with Part 112 (commencing with Section 112.1) <br /> of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. In implementing the spill prevention control <br /> and countermeasure plan, an owner or operator shall fully comply with the latest version of the regulations contained in <br /> Part 112 (commencing with Section 112.1)of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br /> CORRECTIVE ACTION: Implement the SPCC plan, as required. Submit proof of correction to the EHD. <br /> This is (Class 2)Violation. <br /> 7 Code of Fed Regulations 112.5(a), 112.5(b)4010010- Facility has amended SPCC as necessary. <br /> OBSERVATION:The facility failed to amend the Spill Prevention, Control, and Countermeasure(SPCC) Plan within six <br /> months of when there was a change in design, construction, operation, or maintenance, which affects the facility's <br /> discharge potential. <br /> -SPCC plan does not adequately reflect current overfill prevention method. Plan indicates that a liquid gauge is being <br /> used to monitor tank, a liquid gauge was not found while on site. <br /> REGULATION GUIDANCE: (a)Amend the SPCC Plan for your facility in accordance with the general requirements in <br /> § 112.7, and with any specific section of this part applicable to your facility,when there is a change in the facility <br /> design, construction, operation, or maintenance that materially affects its potential for a discharge as described in§ <br /> 112.1(b). <br /> CORRECTIVE ACTION: Ensure that the SPCC Plan has been amended, as required, and it accurately represents <br /> facility design, procedures, and policies currently in place. Provide proof of correction to the EHD. <br /> This is(Minor)Violation. <br /> 50 Code of Fed Regulations 112.8(c)(2)4030013-Containment systems are sufficiently impervious to contain oil. <br /> OBSERVATION: Diked area is not impervious to contain discharged oil. Diked areas must be sufficiently impervious <br /> to contain discharged oil. Immediately provide or repair all diked areas to be sufficiently impervious to contain oil. <br /> - Diked area contained vegetation growing within containment which indicates it is not sufficiently impervious to <br /> contain oil <br /> REGULATION GUIDANCE: 112.8(c)(2)You must ensure that diked areas are sufficiently impervious to contain <br /> FA0009397 PRO516365 SCO01 06/21/2024 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-AST Non-Qualified OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.