COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
3736
>
2800 - Aboveground Petroleum Storage Program
>
PR0523227
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 1:57:22 PM
Creation date
7/30/2024 2:26:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0523227
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0009252
FACILITY_NAME
California Materials, INC
STREET_NUMBER
3736
Direction
S
STREET_NAME
STATE ROUTE 99
City
Stockton
Zip
95215
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3736 S STATE ROUTE 99 Stockton 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STI SP001 Monthly Inspection Checklist <br />Retain until <br />Title: <br />Inspector’s Signature <br />Tank(s) inspected ID <br />Inspection Guidance: <br />> <br />> <br />ITEM STATUS COMMENTS / DATE CORRECTED <br />Tank and Piping <br />1 <br />Is the tank liquid level gauge legible and in good working condition?2 <br />3 <br />Page 1 of 3Monthly Checklist <br />50 | P a ci e <br />Is tank exterior (roof, shell, heads, bottom, connections, fittings, valves, etc.) free of visible <br />leaks? <br />Note: If "No", identify tank and describe leek and actions taken. <br />Is the area around the tank (concrete surfaces, ground, containment, etc.) free of visible <br />signs of leakage? <br />yVes □ No <br />Regulatory facility name and ID number (if applicable) <br />^Yes o No o N/A <br />Yves □ No <br />General Inspection Information:_______________________________ <br />Inspection Date: iims>t ' Prior Inspection Date: <br />Inspector Name (print): QW 1 1 <br />Locally developed checklists are acceptable as long as they are substantially equivalent (as applicable). Inspections of multiple tanks may be captured on one form as <br />long as the tanks are substantially the same. <br />For equipment not included in this Standard, follow the manufacturer recommended inspection/testing schedules and procedures <br />The penodic AST Inspection is intended for monitoring the external AST condition and its containment structure. This visual inspection does not require a Certified <br />Inspector. It shall be performed by an owner's inspector per paragraph 4.1.2 of the standard. <br />Upon discovery of water in the primary tank, secondary containment area, interstice, or spill container, remove promptly or take other corrective action Inspect the liquid <br />for regulated products or other contaminants and dispose of properly. <br />Non-conforming items important to tank or containment integrity require evaluation by an engineer experienced in AST design, a Certified Inspector, or a tank <br />manufacturer who will determine the corrective action. Note the non-conformance and corresponding corrective action in the comment section. <br />Retain the completed checklists for at least 36 months. <br />After severe weather (snow, ice, wind storms) or maintenance (such as coating) that could affect the operation of critical components (normal and <br />emergency vents, valves), an inspection of these components Is required as soon as the equipment is safely accessible after the event.
The URL can be used to link to this page
Your browser does not support the video tag.