COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
2300 - Underground Storage Tank Program
>
PR0231223
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2025 9:09:34 AM
Creation date
8/6/2024 7:47:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231223
PE
2361 - UST FACILITY
FACILITY_ID
FA0002324
FACILITY_NAME
PACIFIC AVE
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
6131 PACIFIC AVE STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PACIFIC AVE 6131 PACIFIC AVE, STOCKTON August 13 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> -Q1 87 PLLD: gross line fail (9/19/23, 4/30/24, 5/17/24) <br /> -Q2 91 PLLD: gross line fail (1/8/24,1/9/24) <br /> -L2 91 STP: high liquid (1/8/24)and fuel (1/9/24,1/10/24) <br /> The DO failed to document all outstanding compliance issues in section 3 on the visual inspection reports that were <br /> previously documented but not responded to appropriately: <br /> -10/20/23: Q1 gross line fail (9/19/23) <br /> -2/9/24: Q2 gross line fail (1/8/24, 1/9/24); L2 high liquid (1/8/24), L2 fuel (1/9/24, 1/10/24) <br /> -5/30/24: Q1 gross line fail (4/30/24) <br /> -6/28/24: Q1 gross line fail (5/17/24) <br /> The DO failed to check and note all required items on the visual inspection reports. <br /> -DO incorrectly marked"Yes"or"NA" in section 7 when follow-up action from the previous DO report had not been <br /> completed appropriately. <br /> 10/20/23, 5/30/24, 6/28/24-Q1 gross line fail (9/19/23,4/30/24, 5/17/24) <br /> 2/9/24-Q2 gross line fail (1/8/24 and 1/9/24), L2 high liquid (1/8/24), L2 fuel (1/9/24, 1/10/24) <br /> -DO incorrectly marked"Yes"or"NA"for question 2 of section 8 when each alarm since the previous inspection had <br /> not been responded to appropriately. <br /> 9/22/23, 5/3/24, 5/30/24-Q1 gross line fail (9/19/24,4/30/24, 5/17/24) <br /> 1/12/24-Q2 gross line fail (1/8/24, 1/9/24), L2 high liquid (1/8/24), L2 fuel (1/9/24, 1/10/24) <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall review the alarm history since the <br /> previous inspection, check that each alarm was documented and responded to appropriately, and attach a copy of the <br /> alarm history with documentation taken in response to any alarms to the inspection report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing hat designated operators performing inspections <br /> at this facility are including all of the required information on the reports. <br /> This is a repeat violation (Class 2) Violation. <br /> 59 CA Code of Regulations 2712(b)(1-2)2030001 - Records of release detection monitoring and maintenance properly <br /> maintained (TCR 9d). <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br /> -Work orders documenting appropriate response to alarms on 9/19/23, 1/8/24, 1/9/24, 1/10/24,4/30/24, and 5/17/24) <br /> -Monitoring System Certification test results for 8/11/21 <br /> -Spill bucket test results for 8/11/21 (all)and 11/22/21 (91 and diesel only) <br /> -Overfill test results for 3/29/22 (87 only) <br /> REGULATION GUIDANCE:These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; <br /> (3)results of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6)results of <br /> inventory readings and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last <br /> three years on site. Submit copies of any missing work orders and alarm records to the EHD. <br /> FA0002324 PR0231223 SCO01 08/13/2024 <br /> EHD Rev.12/06/2021 Page 7 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.