My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
30350
>
2800 - Aboveground Petroleum Storage Program
>
PR0527885
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2024 10:02:18 AM
Creation date
8/6/2024 10:00:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0527885
PE
2832
FACILITY_ID
FA0009761
FACILITY_NAME
CEMEX CONST MATERIALS PACIFIC LLC
STREET_NUMBER
30350
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95377
APN
25313011
CURRENT_STATUS
01
SITE_LOCATION
30350 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />May 14, 2024 <br /> Facility Address: <br /> 30350 S TRACY BLVD, TRACY <br /> Facility Name: <br /> CEMEX CONST MATERIALS PACIFIC LLC <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 719 □ V □ R □ COSFailed to locate properly or provide sufficient secondary containment for mobile/portable containersCFR 112.8(c)(11) <br /> 720 □ V □ R □ COSFailed to take corrective action on buried piping when exposed for any reasonCFR 112.8(d)(1) <br /> 721 □ V □ R □ COSFailed to provide corrosion protection for buried pipingCFR 112.8(d)(1) <br /> 722 □ V □ R □ COSFailed to cap/blank-flange connection at transfer point and mark its origin if not in serviceCFR 112.8(d)(2) <br /> 723 □ V □ R □ COSFailed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contractionCFR 112.8(d)(3) <br /> 724 □ V □ R □ COSFailed to regularly inspect aboveground valves, piping, and appurtenancesCFR 112.8(d)(4) <br /> 725 □ V □ R □ COSFailed to conduct integrity and leak testing on buried piping any time it is worked onCFR 112.8(d)(4) <br /> 726 □ V □ R □ COSFailed to adequately warn vehicles entering facility to protect piping and other transfer operationsCFR 112.8(d)(5) <br /> 727 □ V □ R □ COSPlan failed to adequately describe overfill prevention methods for each containerCFR 112.7(a)(1), <br />112.8(c)(8) <br />Other Violations <br /> 4010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 4020 □ V □ R □ COSUnlisted Training violation See below <br /> 4030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 4040 □ V □ R □ COSUnlisted Release/Leaks/Spills violation See below <br /> 4050 □ V □ R □ COSUnlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 112 CFR 112.20(e) Failure to complete and maintain a Substantial Harm Criteria certification. <br />OBSERVATION: The facility failed to discuss the Substantial Harm Criteria certification in the SPCC plan. <br />REGULATION GUIDANCE: (e) If the owner or operator of a facility determines pursuant to paragraph (a)(2) of this <br />section that the facility could not, because of its location, reasonably be expected to cause substantial harm to the <br />environment by discharging oil into or on the navigable waters or adjoining shorelines, the owner or operator shall <br />complete and maintain at the facility the certification form contained in appendix C to this part and, in the event an <br />alternative formula that is comparable to one contained in appendix C to this part is used to evaluate the criterion in <br />paragraph (f)(1)(ii)(B) or (f)(1)(ii)(C) of this section, the owner or operator shall attach documentation to the <br />certification form that demonstrates the reliability and analytical soundness of the comparable formula and shall <br />notify the Regional Administrator in writing that an alternative formula was used. <br />CORRECTIVE ACTION: Complete and maintain at the facility the Substantial Harm Criteria certification form. <br />Submit proof of correction to the EHD. <br />This is a Class II violation. <br />FA0009761 PR0527885 SC001 05/14/2024 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 4 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.