Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:52 am <br />10:06 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: THE COOPER COMPANY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1405 TRAILWOOD AVE, MANTECA 95336 <br />Date: 07/21/2023Name of Facility: PARK WEST HOA WEST <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #4 Safety Equipment <br />OBSERVATIONS: Life ring throw rope length is less than the max width of the pool. Provide throw rope with at least max <br />the width of the pool today. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Both single hand rails and the double hand rails are loose. Secure all hand rails in 1 week. Corrected on <br />site. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 120 <br />7.8 <br />2.6 <br /><30 Combined chlorine:ppm <br />NOTES <br />Pool inspection. <br />Influent 7 PSI <br />Effluent 1 PSI <br />Light and GFCI are working. <br />Chemical kit and log are on site. <br />Life ring and body hook are on site. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000923 PR0360104 SC001 07/21/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD