My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3511
>
3600 - Recreational Health Program
>
PR0360087
>
COMPLIANCE INFO_PRE 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2024 2:48:25 PM
Creation date
8/29/2024 2:45:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2020
RECORD_ID
PR0360087
PE
3611
FACILITY_ID
FA0003013
FACILITY_NAME
ECONO LODGE
STREET_NUMBER
3511
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418017
CURRENT_STATUS
01
SITE_LOCATION
3511 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JUOUIN <br /> Environmental Health Department <br />N I \f" <br />Time In: 10.11 am <br />Time Out: 10:47 am <br />Swimming Pool Official Inspection Report <br />Name of Facility: ECONO LODGE Date: 08/01/2019 <br />Address: 3511 N TRACY BLVD, TRACY 95376 <br />Owner/Operator: AJRT HOLDINGS INC Telephone: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Inspection Type: INSPECTION/REINSPECTION (Chargeable) <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The free chlorine level in the pool is 0.6 ppm. Increase free chlorine level to 2.0 to 10.0 ppm. Correct <br />immediately to avoid pool remaining closed. <br />Approximately 1/2 gallon of 10% added. <br />CAL CODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br />#2 Pool Enclosure <br />OBSERVATIONS: The pool gate does not close completely (per Manager, a car ran into the gate and a work order has <br />been submitted). <br />Properly repair pool gate ASAP. <br />CALCODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br />3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br />perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br />at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br />arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br />are allowed lithe enclosure was constructed prior to July 1994. (CBC 3119B) <br />#35 Flow Meters <br />OBSERVATIONS: The flowmeter is not functioning properly. Repair/replace flowmeter by 1 week. <br />CAL CODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />FA0003013 PR0360087 SC333 08/01/2019 <br />END 36-01 Rev. 06/30/15 Page 1 of 2 Swimming Pool OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.