Laserfiche WebLink
SANA,JOAQUIN <br /> Environmental Health Department <br />COUNTY <br />Swimming Pool Official Inspection Report <br />I Facility Name and Address: ECONO LODGE, 3511 N TRACY BLVD, TRACY 95376 <br />#2 Pool Enclosure <br />OBSERVATIONS: The pool gate does not close completely (per Manager, a car ran into the gate and a work order has <br />been submitted). <br />Properly repair pool gate ASAP. <br />CAL CODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br />3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br />perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br />at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br />arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br />are allowed if the enclosure was constructed prior to July1994. (CBC 3119B) <br />#3 Safety Signs <br />OBSERVATIONS: The emergency signage lacks the name and address of the facility. Write in the name and address of <br />the facility on the signage today. Corrected on site. <br />The pool/spa hours are not listed on the signage. Write in the pooVspa hours on the signage today. Corrected on site. <br />CAL CODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br />#35 Flow Meters <br />OBSERVATIONS: The flowmeter is not functioning properly. Repair/replace flowmeter by 1 week. <br />CAL CODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />#36 Pressure and Vacuum Gauges <br />OBSERVATIONS: The effluent gauge is not functioning properly. Repair/replace effluent gauge by 1 week. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate: <br />Cyanuric acid: <br />NOTES <br />0 gpm Chlorine: >20.0 ppm Temp: ° F <br />50 ppm pH: 7.4 Combined chlorine: 0.2 ppm <br /> <br />FA0003013 PR0360087 SC001 07/29/2019 <br />El-ID 36-01 Rev. 06/30/15 <br /> Page 2 of 3 <br /> Swimming Pool OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com