Laserfiche WebLink
SCOPE OF WORK <br />POOL < m <br />Drain Pool � z <br />Install Aquastar Channel Drain on Main Drain 0 z Q Y <br />Temporarily Abandon Skimmer Equalizer Lines. Lines will be 0 < <br />plugged with threaded plugs. This is meant as a temporary <br />solution until next replaster. <br />1 0 <br />POOL SPECIFICATIONS <br />Surface Area — 801 Sq Ft <br />Perimeter —122 Ft <br />Volume — 26,960 gal <br />Turnover rate @ 6 hrs = 74.8 gpm <br />ry EXISTING EQUIPMENT LIST <br />POOL <br />FILTER — FNS Plus 56 Sq Ft DE <br />PUMP — Hayward 1.5 hp (90 gpm @ 60TDH) <br />� SANITIZER — Rainbow Tab Feeder <br />"v FLOW METER —Blue White <br />SPA <br />Drain Spa <br />E, Install Aquastar Channel Drain in Main Drain — Both Suctions <br />For Main Drain and Jet Booster are underneath Cover <br />Temporarily Abandon Skimmer Equalizer Lines. Lines will be <br />plugged with threaded plugs. This is meant as a temporary W N <br />solution until next replaster. <br />Q N 04 <br />SPA SPECIFICATIONS Q E Lo <br />Surface Area — 95 Sq Ft Q = CU <br />21 P Perimeter 35 Ft <br />0 <br />N Volume — 2130 gal Z Q (D U <br />° I Turnover rate @ 30 min = 71 gpm <-0 <br />t °W Q d- o <br />EXISTING EQUIPMENT LIST Q ((} p <br />SPA Z . ''_' <br />FILTER —Nautilus 46 Sq Ft D.E. U) <br />PUMP — Starite 1 hp (75 gpm @ 60 TDH) Main Drain Cover Being Installed m <br />BOOSTER PUMP — Starite 2hp (115 gpm @ 60TDH) Q <br />HEATER — Raypak 400,000 btu <br />SANITIZER — Rainbow Tab Feeder Channel Drain Flat gate <br />-, FLOW METER — Blue White Anti-Entrapment Suction Cutlet Cover <br />and Frame <br />`SGB Series aqws ear swdon cuftcowscwroWt <br />tt* i <br />ftdwtSpedficaionsheet !Vkg7mb 8*wFb iandF aSafetyAct gkSWANSWmigs- 7} <br />The Unblockable' <br />>W <br />ff <br />tideraMe,�a�s :: <br />} <br />1 <br />SCALE 1/8'' = 1' <br />Aquastar 32" Channel Drain i <br />VGB Compliant with single suction Aquastar 32" Channel Drain; <br />Unbiockable Drain 3" Minimum at inside height (above suction pipe) VGB Compliant with single suction 3 <br />Per manufacturer's Instruction Unblockable Drain 3" Minimum at inside height (above suction pipe) c� <br />mr <br />Per manufacturer's Instruction <br />Dart Numbm J Color <br />2" Minimum at outside height [ r w <br />Per manufacturer's Instruction �� 2" Minimum at outside height <br />:. <br />... Per manufacturer's Instruction <br />d .. <br />sz�oF€�oae�tc <br />�. . <br />+� V <br />ca <br />>5 <br />.p <br />a <br />Sump Built per Manufacturer's Instruction _ c <br />Sump Built per Manufacturer's Instruction - <I <br />N �^ <br />HYDROSTATIC RELIEF VALVE (TYP) ` I 3rc ' (� <br />— HYDROSTATIC RELIEF VALVE (TYP) trcr,sc+t <br />SUCTION LINE - aBSRnt sc p <br />SUCTION LINE riy <br />CHANNEL DRAIN INSTALLATION <br />MAIN DRAIN CHANNEL DRAIN INSTALLATION <br />MAIN DRAIN <br />