My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
12550
>
2800 - Aboveground Petroleum Storage Program
>
PR0537957
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2024 3:26:08 PM
Creation date
9/6/2024 3:24:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0537957
PE
2832
FACILITY_ID
FA0021911
FACILITY_NAME
HEARTLAND EXPRESS INC
STREET_NUMBER
12550
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
12550 S Harlan Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Tier II Inspection Report <br />Date: <br />August 30, 2024 <br /> Facility Address: <br /> 12550 S Harlan RD, Lathrop <br /> Facility Name: <br /> HEARTLAND EXPRESS INC <br /> □ OUT □ R □ COS4030037 - Appropriate (general) containment/diversionary structures/equipment have been <br />provided <br />Code of Fed <br />Regulations 112.7(c) <br /> 190 <br /> □ OUT □ R □ COS4010004 - Impracticability of containment/diversionary items, if claimed, is PE demonstrated and <br />certified <br /> 191 <br /> □ OUT □ R □ COS4030033 - Periodic integrity/leak testing performed with impracticability claimCode of Fed <br />Regulations 112.7(d), <br />25270.4.5(a) <br /> 192 <br /> □ OUT □ R □ COS4010005 - If claiming impracticability of containment/diversionary items a contingency plan has <br />been included <br />Code of Fed <br />Regulations 112.7(d)(1) <br /> 193 <br /> □ OUT □ R □ COS4010006 - If claiming impracticability written commitment of manpower, equipment, and materials <br />provided <br />Code of Fed <br />Regulations 112.7(d) <br />(2), 25270.4.5(a) <br /> 194 <br /> □ OUT □ R □ COS4010023 - Employee training and spill prevention briefings discussed in SPCC planCode of Fed <br />Regulations 112.7(f)(1), <br />112.7(f)(3) <br /> 195 <br /> □ OUT □ R □ COS4020001 - Training provided for op /maint of equip, discharge procedures, laws/regs, general fac <br />ops, and SPCC <br />Code of Fed <br />Regulations 112.7(f)(1) <br /> 196 <br /> □ OUT □ R □ COS4010022 - Person has been designated as accountable for discharge prevention and reports to <br />management <br />Code of Fed <br />Regulations 112.7(f)(2) <br /> 197 <br /> □ OUT □ R □ COS4020002 - Spill prevention briefings are conducted annuallyCode of Fed <br />Regulations 112.7(f)(3) <br /> 198 <br /> □ OUT □ R □ COS4010024 - SPCC addresses security measures-lighting, access to handling/storage, <br />valves/pumps/transfer equip <br />Code of Fed <br />Regulations 112.7(g) <br /> 199 <br /> □ OUT □ R □ COS4030001 - Handling areas, valves, pumps/starter controls, load/unload connections secured, <br />lighting adequate <br />Code of Fed <br />Regulations 112.7(g) <br /> 200 <br /> □ OUT □ R □ COS4010025 - SPCC adequately discusses facility tank car and tank truck loading/unloading rackCode of Fed <br />Regulations 112.7(h) <br /> 201 <br /> □ OUT □ R □ COS4030002 - Loading rack containment has capacity to contain single largest compartment of tank <br />car/truck <br />Code of Fed <br />Regulations 112.7(h)(1) <br /> 202 <br /> □ OUT □ R □ COS4030003 - Vehicular departure warning system in place at facility with a loading/unloading rackCode of Fed <br />Regulations 112.7(h)(2) <br /> 203 <br /> □ OUT □ R □ COS4030016 - Brittle fracture evaluation of field-constructed aboveground tanks performed 204 <br /> □ OUT □ R □ COS4030034 - Oil filled operational equipment containment standards are metCode of Fed <br />Regulations 112.7(k) <br /> 205 <br /> □ OUT □ R □ COS4010027 - Facility drainage or drainage controls adequately discussedCode of Fed <br />Regulations 112.7(a)(3) <br />(iii) <br /> 206 <br /> □ OUT □ R □ COS4030035 - Facility drainage adequately restrained unless conditions metCode of Fed <br />Regulations 112.8(b)(1) <br /> 207 <br /> □ OUT □ R □ COS4030005 - Valves used for drainage are manual (not flapper-type) to prevent a dischargeCode of Fed <br />Regulations 112.8(b)(2) <br /> 208 <br /> □ OUT □ R □ COS4030008 - Drainage from undiked areas or diversion systems designed to retain final discharge in <br />facility <br />Code of Fed <br />Regulations 112.8(b) <br />(3), 112.8(b)(4) <br /> 209 <br /> □ OUT □ R □ COS4030009 - Lift pumps provided for treated drainage waters when more than one treatment unitCode of Fed <br />Regulations 112.8(b)(5) <br /> 210 <br /> □ OUT □ R □ COS4010029 - Adequate discussion of all bulk storage containers located at the facilityCode of Fed <br />Regulations 112.8(c) <br /> 211 <br /> □ OUT □ R □ COS4030012 - Material and construction of all containers are compatible with the material storedCode of Fed <br />Regulations 112.8(c)(1) <br /> 212 <br /> □ OUT □ R □ COS4030010 - Adequately sized secondary containment provided and maintained for bulk storage <br />containers <br />Code of Fed <br />Regulations 112.8(c)(2) <br /> 213 <br />FA0021911 PR0537957 SC001 08/30/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Tier II OIRPage 9 of 12 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD