My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
6465
>
3600 - Recreational Health Program
>
PR0360593
>
COMPLIANCE INFO_PRE 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2024 4:36:01 PM
Creation date
9/6/2024 4:34:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2020
RECORD_ID
PR0360593
PE
3612
FACILITY_ID
FA0002425
FACILITY_NAME
WESTPOINTE APARTMENTS NE SPA
STREET_NUMBER
6465
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09405029
CURRENT_STATUS
01
SITE_LOCATION
6465 N WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,..•.f <br />,b9.54f(y. <br />. ..=.06.4'%• z.... 111., • P <br />11.1.1.1_ ,,.•••::.41; , :.< <br />4tigiyik <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.siqov.orq/ehd <br />Swimming Pool Official Inspection Report <br />Time In: 1:30 pm <br />Time Out: 2:00 pm <br />Name of Facility: VVESTPOINTE APARTMENTS PHASE II Date: 06/02/2016 <br />Address: 6465 N WEST LN, STOCKTON 95210 <br />Owner/Operator: PATMON COMPANY INC Telephone: (209) 951-4391 <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#10 Disinfectant Residual MAJOR <br />OBSERVATIONS: 0 ppm free chlorine. Provide 3 to 10 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br />#29 Recirculation System Operation MAJOR <br />OBSERVATIONS: Pump not working. Repair to provide 1 turn over every 30 minutes for spa. <br />CALCODE DESCRIPTION: Recirculation system shall be in operation whenever the pool is available for use and additional times as <br />needed to maintain clear pool water. (CCR 65525) <br />#37 Electrical Hazards MAJOR <br />OBSERVATIONS: GCFI could not be tested, or reset after "tripped"; electrical panel not screwed in and breakers seemed <br />not safely housed. . Pool is closed. Repair immediately by licensed electrician. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br />Califomia Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br />fault circuit interrupter. (CBC 3160B) <br />#3 Safety Signs <br />OBSERVATIONS: Post "No Swimming After Dark" sign on deck since there is no pool light at this time. <br />Address on sign faded. Relabel. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br />FA0002425 PR0360593 SC001 06/02/2016 <br />EHD 36-01 Rev, 06/30/15 Page 1 of 3 Swimming Pool OIR
The URL can be used to link to this page
Your browser does not support the video tag.