Laserfiche WebLink
APPENDIX E <br />HOT WATER DEMANDS <br />FIXTURES NO. OF <br />UNITS <br />X GPH = TOTAL GPH <br />X = o <br />X = o <br />X = 0 <br />X = o <br />X = o <br />X = o <br />X = 0 <br />X = 0 <br />X = o <br />X = o <br />X = o <br />X = o <br />Calculating the BTU (British Thermal Units) for kitchen gas water heater: <br />GHP x 60 degrees rise x 11* = <br />*8.33 lbs./gal. of water = 11.1 (rounded off= 11) <br />0.75 (thermal efficiency of gas) <br />The gas hot water heater with at least a rating of BTU <br />Calculating the KW (kilowatt) requirement for kitchen electric water heater: <br />Total GPH = GPH = KW* <br /> <br />gal/KWH gal/KWH <br />*KW.... GPH x °RISE x 8.33 <br />.98 x 3412 BTU <br />KW <br />Please make the necessary changes or alterations, as indicated above, for the minimum supply of hot water for the food <br />establishment. The recovery rate of the properly sized water heater must meet the peak demands of the total GPH. <br />EHD 16-01 22 PLAN CHECK GUIDE <br />BTU <br />7/5/17