My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 3:56:26 PM
Creation date
9/25/2024 4:56:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231820
PE
2361 - UST FACILITY
FACILITY_ID
FA0003826
FACILITY_NAME
UNFI GROCERS DISTRIBUTION, INC (STOCKTON)
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1990 N PICCOLI RD STOCKTON 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAID dOAQUIN <br />COUNTY <br />Environmental Health Department <br />EHD Rev. 12/06/2021 <br />FA0003826 PR0231820 SCO01 11/13/2024 <br />Page 5 of 6 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />CP22 - UST FULL Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />UNFI GROCERS DISTRIBUTION INC <br />1990 N PICCOLI RD STOCKTON <br />November 13 2024 <br />87 <br />CA Code of Regulations <br />2060021 - Striker plate installed and positioned correctly. <br />❑ OUT <br />❑ R ❑ COS <br />2631(c), 2662(d) <br />88 <br />CA Code of Regulations <br />2060007 - Primary and secondary containment designed and constructed to an engineering <br />❑ OUT <br />❑ R ❑ COS <br />2631(b&d), 2666(b&e) <br />specification. <br />89 <br />CA Health and Safety <br />2060008 - Enhanced leak detection testing performed before the tank is placed in use <br />❑ OUT <br />❑ R ❑ COS <br />Code 25290.10) <br />90 <br />CA Code of Regulations <br />2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />D OUT <br />❑ R ❑ COS <br />2666(b)(2) <br />or repair needed <br />91 <br />CA Health and Safety <br />2010 - Administration/Documentation - General <br />❑ OUT <br />❑ R ❑ COS <br />Code 25291(e) <br />92 <br />2015 - Administrative/Documentation - General Local Ordinance <br />❑ OUT <br />❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />5 <br />CA Code of Regulations 2632(d), 2641(h) 2030041 - A current facility plot plan is maintained and has been submitted. <br />OBSERVATION: An accurate UST Monitoring Site Plan was not submitted. The annular sensor was located on the <br />wrong side of the tank. <br />REGULATION GUIDANCE: A site plan must be submitted identifying the locations where monitoring will be performed. <br />The site plan must show the general layout of tanks and clearly identify locations of the following equipment, if <br />installed: 1) monitoring panels; 2) in -tank liquid level probes (if used for leak detection); 3) devices monitoring tank <br />annular spaces or vault; 4) devices monitoring product piping; 5) devices monitoring fill piping; 6) devices monitoring <br />vent piping; 7) devices monitoring vapor recovery piping; 8) devices monitoring vent/transition sumps; 9) devices <br />monitoring under -dispenser containment; 10) line leak detectors; and 11) devices monitoring any other secondary <br />containment areas. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a repeat violation (Class 2) Violation. <br />10 <br />CA Code of Regulations 2638(c), 2638(d) 2030074 - Annual Monitoring System Certification Form to the CUPA within <br />30 days of completion of the test. <br />OBSERVATION: A monitoring system certification and leak detector testing was performed on 11 /15/23 A test report <br />has not been submitted to the EHD or the California Environmental Reporting System (CERS). <br />REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the test. <br />CORRECTIVE ACTION: Immediately provide this report to the EHD. <br />This is (Class 2) Violation. <br />56 <br />CA Code of Regulations 2716(a -e) 2030013 - DO inspections completed at least every 30 days and meet all <br />requirements (TCR 12). <br />OBSERVATION: The designated operator failed to check and note all required items on the visual inspection reports. <br />The incorrect and missing information included the following from the inspection reports: <br />-The reports contain an incorrect CERS ID. <br />-The 2/2/24 and 3/1/24 reports had a blank section V and were not signed by the owner/operator. <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required testing <br />EHD Rev. 12/06/2021 <br />FA0003826 PR0231820 SCO01 11/13/2024 <br />Page 5 of 6 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.