Environmental Health Department <br />Telephone: () - Owner/Operator: MOSSDALE LANDING OWNER LLC <br />Inspection Type: Routine <br />Address: 18008 GOLDEN VALLEY PKWY, LATHROP 95330 <br />Date: 07/01/2024Name of Facility:MOSSDALE LANDING APARTMENTS <br />Reinspection on or after: <br />Swimming Pool Official Inspection Report <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public <br />health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />VIOLATIONS AND CORRECTIVE ACTIONS <br /> #10 Disinfectant Residual <br />OBSERVATIONS: The chlorine level of the spa is 2.0ppm. Immediately increase the chlorine level of the spa to the range of 3.0 <br />to 10.0ppm or face closure. <br />A splash of chlorine was added to the spa . Re-checked chlorine level is 7.2ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall <br />maintain the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with <br />cyanuric acid or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to <br />10.0 ppm free chlorine or 4.0 ppm bromine. (CCR 65529) <br />This is (Major) Violation. <br />MAJOR <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The handrail at the spa is very loose. Facility has closed the spa to users. Repair to proper by 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a <br />point above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) <br />Pool operator shall keep ladders and handrails well maintained. (CCR 65535) <br />This is (Minor - Food) Violation. <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: The plaster in the spa has black streaks (not slimy like algae). Take action to clean black streaks from the <br />spa plaster. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated <br />brushing, and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC <br />3108B) <br />This is (Minor - Food) Violation. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0548839 07/01/2024 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD