COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7400
>
1900 - Hazardous Materials Program
>
PR0531214
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2024 4:23:47 PM
Creation date
10/8/2024 4:21:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0531214
PE
1921
FACILITY_ID
FA0019004
FACILITY_NAME
CITY OF STOCKTON MUD WELLS-3R
STREET_NUMBER
7400
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09404003
CURRENT_STATUS
01
SITE_LOCATION
7400 N WEST LN
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Hazardous Materials Program Inspection Report <br />Date: <br />May 10, 2024 <br /> Facility Address: <br /> 7400 N WEST LN, STOCKTON <br /> Facility Name: <br /> CITY OF STOCKTON MUD WELLS-3R <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 6 HSC 25505(a)(2) Failed to electronically submit a site map with all required content. <br />OBSERVATION: A site map was not completed and submitted as part of the business plan due to missing the <br />following elements: <br />- No loading area indicated <br />- No evacuation staging area <br />- No Access/Exit points <br />REGULATION GUIDANCE: site map that contains north orientation, adjacent streets, access and exit points, <br />evacuation staging areas, hazardous material handling and storage areas, emergency response equipment, and, if <br />present, loading areas, internal roads, storm and sewer drains, and emergency shutoffs, as well as additional map <br />requirements the governing body of the unified program agency finds necessary. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, upload the correct or updated information, and submit to the EHD for approval. <br />This is a minor violation. <br /> 7 HSC 25505(a)(3) Failed to electronically submit an adequate ER procedures for a release or threatened release. <br />OBSERVATION: The emergency response(ER) procedures were lacking or inadequate due to the following <br />reasons: <br />- Under section E: E3 is not filled in <br />- Under section H: H6 mentions portable gas cylinders and tanks, none were found on site. <br />REGULATION GUIDANCE: A business plan shall include the following emergency response procedures for a <br />release or threatened release of hazardous materials, including, but not limited to, the following: <br /> - immediate notification of local emergency personnel and the Environmental Health Department (EHD) <br /> - procedures for the mitigation of a release or threatened release to minimize any potential harm or damage to <br />persons, property, or the environment <br /> - evacuation plans and procedures, including immediate notice, for the site <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, upload the correct or updated information, and submit to the EHD for approval. <br />This is a Class II violation. <br />FA0019004 PR0531214 SC001 05/10/2024 <br />EHD 19-01 Rev. 12/06/2021 Hazardous Materials Program OIRPage 2 of 3 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD