My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15250
>
2800 - Aboveground Petroleum Storage Program
>
PR0539991
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 3:34:32 PM
Creation date
10/23/2024 11:13:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0539991
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0021886
FACILITY_NAME
Love's Travel Stop #538
STREET_NUMBER
15250
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
Lodi
Zip
95242
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
15250 N THORNTON RD Lodi 95242
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />October 14, 2024 <br /> Facility Address: <br /> 15250 N THORNTON RD, Lodi <br /> Facility Name: <br /> Love's Travel Stop #538 <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.3 4030038 - SPCC has been implemented. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan was not implemented, as required. <br />The following has been mentioned in the plan but is not being followed: <br />- Plan mentions that for their oil handling procedure, an employee is present while above ground storage tank is being <br />filled by truck operator. Per Spring Falkenberg, an employee is not present during this process. <br />- Plan mentions that general manager will sign all inspections for aboveground storage tanks, no signature was found. <br />- Plan mentions that monthly and annual inspections will remain on site for 3 years, not all inspections for the past 36 <br />months were available for review. <br />- Plan mentions that employee training records for past 36 months will be on site but only training for 2024 was <br />available. <br />- Plan mentions that the spill kit is located northwest of the main store. There was no spill kit available, Instead the <br />spill kit materials were found in the maintenance room. <br />REGULATION GUIDANCE: 112.3: The owner or operator or an onshore or offshore facility subject to this section must <br />prepare in writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter “SPCC Plan” or <br />“Plan”),” in accordance with § 112.7 and any other applicable section. 25270.4.5.(a): An owner or operator shall <br />conduct periodic inspections of the storage tank to ensure compliance with Part 112 (commencing with Section 112.1) <br />of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. In implementing the spill prevention control <br />and countermeasure plan, an owner or operator shall fully comply with the latest version of the regulations contained in <br />Part 112 (commencing with Section 112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br />CORRECTIVE ACTION: Implement the SPCC plan, as required. Submit proof of correction to the EHD. <br />This is a repeat violation (Class 2) Violation. <br /> 3 <br />Code of Fed Regulations 112.5(a), 112.5(b) 4010010 - Facility has amended SPCC as necessary. <br />OBSERVATION: The facility failed to amend the Spill Prevention, Control, and Countermeasure (SPCC) Plan within six <br />months of when there was a change in design, construction, operation, or maintenance, which affects the facility’s <br />discharge potential. <br />- In the SPCC plan, Stephanie Machuca is listed as the general store manager. At time of inspection, Spring <br />Falkenberg is now the general store manager. <br />REGULATION GUIDANCE: (a) Amend the SPCC Plan for your facility in accordance with the general requirements in <br />§ 112.7, and with any specific section of this part applicable to your facility, when there is a change in the facility <br />design, construction, operation, or maintenance that materially affects its potential for a discharge as described in § <br />112.1(b). <br /> 7 <br />FA0021886 PR0539991 SC001 10/14/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 9 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD