My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3780
>
2300 - Underground Storage Tank Program
>
PR2600076
>
INSTALL_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2026 2:03:26 PM
Creation date
10/29/2024 8:54:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2024
RECORD_ID
PR2600076
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0005924
FACILITY_NAME
H&M PETROLEUM CORP
STREET_NUMBER
3780
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3780 100 N TRACY BLVD TRACY 95304
Suite #
100
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTIONS PRIOR TO FIRST FUEL_ DELWERY <br /> j} Verification of leak monitoring communication for all installed vacuum, pressure, or hydrostatic (VPH) <br /> components, including piping, sumps, under dispenser containment sumps (LJDCs), and all chase <br /> lines. Communication at end points of each vacuum zone and each vacuum monitored sump must be <br /> verified independently in operating condition <br /> k) Verification of the dispenser footprints contained by the UDCs. Any potential leaks from piping and <br /> fuel filters must drain directly into UDCs, <br /> 1) Enhanced Leak Detection (ELD) testing, after facility is in operating condition. Appropriate test <br /> notification and tester certifications are required. Passing ELD test results must be submitted to the <br /> E H D within 60 days of testing. ELD test results rriust be received by the E H D before written approval <br /> to deposit fuel will be issued- <br /> m) Verification of liquid and vapor tightness component installation (shroud boots and band clamps for <br /> spill containers, appropriate rubber-type gasket or clamps on lids on all fill, vent,and STP sumps, etc,). <br /> n) Verifcation of overfill prevention: Measurement of dfop tubes to verify 95% tank volume shut off, <br /> verification of external and ibleNisual alarm activation when tank is SO%full,or other approved method- <br /> o) Spill bucket test- Verify minimum 5-gallon capacity- Pass a one hour hydrostatic test (ar equivalent)- <br /> Verify proper drainage method, <br /> p) Monitoring system functionality; Functionality of the monitoring system, including all liquid and vacuum <br /> sensors, must be verified to ensure it meets the requirements of CCR Title 23 and Califomia Health & <br /> Safety Code (HSC) Chapter 6.7. <br /> Thanks, <br /> Stephanie Charissa <br /> Direct: 916-343-3857 <br /> Service Station Systems,Inc. I Able Maintenance,Inc. <br /> From: EH-UST<ust@sjgov.org> <br /> Sent: Monday, February 2, 2026 3:49 PM <br /> To:Stephanie Charissa<Stephanie.Charissa@servicestationsystems.com>; EH-UST<ust@sjgov.org> <br /> Cc:Shea Fuller<Shea.Fuller@ablemaintenance.com> <br /> Subject: RE: Inspection Request SR0087879-3788 N Tracy Blvd <br /> Hi Stephanie, <br /> Is this for a new install? If so, can you please identify which inspections from the approval letter you would <br /> like to request? <br /> Thank you, <br /> Stacy Rivera <br /> Lead Sr.Registered Environmental Health Specialist <br /> San Joaquin County Environmental Health Department <br /> 1868 E.Hazelton Ave.,Stockton,CA 95205 <br /> phone(209)616-3043 <br /> fax(209)468-3433 <br /> *Test notifications and test results should be sent to the general UST email:ust@sjgou.org* <br />