Laserfiche WebLink
(;U11V <br /> ° c°G SANJ0AQUIN Environmental Health Department <br /> COUNTY Linda Turkatte, REHS, Director <br /> g1.lin6 Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada, REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu, REHS <br /> July 24, 2024 <br /> Sarah Jablonsky <br /> Construction Manager <br /> Walton Engineering <br /> P.O Box 1025 <br /> West Sacramento. <br /> Re: Triangle Plaza Tracy SR0087879 <br /> 3788 Tracy Blvd <br /> Tracy, 95304 <br /> The San Joaquin County Environmental Health Department (EHD) has completed a review of <br /> the application for a permit to install an underground storage tank (UST) system at the above <br /> noted address. Please provide the following additional information and address the <br /> comments: <br /> 1. Your permit application states diesel as the product that will be stored, your parts <br /> list on drawings page PET 8 under tank hardware says Bio-Diesel, Clarify the <br /> correct substance that will be stored and provide updated paperwork. <br /> 2. On Page 7 of the Application for Underground Storage Tank Installation Permit, <br /> section G overfill prevention equipment add OPW model number 71 SOM-412C for <br /> E85 all together will be 2. And on page 8, section I- monitoring, add sensor 323 also <br /> for E-85 and turn in new page 7 and 8. <br /> 3. Cut sheets: Provide 1. tank charts cut sheet, the one you sent were not the <br /> acceptable types, 2) provide Monitoring panel TLS 450 plus cut sheet. <br /> 4. Compatibility: Provide E85 compatibility with Unisource flex connector <br /> 5. Tank Chart: Provide tank chart for 6,000 gallon end tank. <br /> 6. Buoyancy calculations: Provide buoyancy calculations with a professional engineer <br /> signature and stamp, the one you provided did not include a stamp. <br /> 7. Drawings: on page PET-1, fuel system keynotes #15 say concrete tank slab will be <br /> 8 inches buoyancy calculations states 9 inches provide the correct inches with <br /> updated documentations. <br /> 8. Drawings: Provide new drawings with sensor holder mounting and provide new <br /> drawings showing vacuum zones. <br /> 9. Drawings: Your drawings show vacuum tubes with ball valves at some points. <br /> Provide new drawings with no ball valves, I believe ball valves can only be at the <br /> vacuum tube ends. <br /> 10.Furthermore, if the substance is biodiesel provide the grade such Bio20, Bio99. <br /> The grade must be provided and make changes everywhere from diesel to <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />