Laserfiche WebLink
S[EC=110[ ] ELECTRICAL OFFSET FRAME, <br /> "FLAT" GONG. TOP, NO PAVING nvROUTE CONDUITS AND INSTALL o 6-) <br /> SMOOTH FINISH SEAL-OFFS, AS REQUIRED U <br /> (OR MATCH (E)) PIPE BURY VARIES BY SIZE z /\/\/ _ Z <br /> AND PAVING CONDITIONS, // PRODUCT SHEAR VALVE DISPENSER, TYP � _ <br /> " SQ. STEEL SEE MIN. REQUIREMENTS, A.G. W/ FUSIBLE LINK, TYP. O O <br /> TUBE, CON(. FILLED HEREIN -h- (VAPOR SHEAR VALVE ISLAND / DRIVE SLAB Z �(1 U c� O <br /> CON(. w W/ FUSIBLE LINK, 5I1"I.) W cv <br /> PAINT (WHITE) : LQ cfJ <br /> SHERWIN WILLIAMS a . _ z w - MINI HYDRO. SENSOR, TYP. �. Z X O c� <br /> b a ATMOSPHERIC MANOMETER TYP. --- - <br /> PROTECTIVE 4 MARINE a >n. W/IN LIQUID RESERVOIR ° ° ° 4 Z O W r <br /> COATING DTM ACRYLIC S L1=CT . Q ° -- _ _ _ _ -- Z � m <br /> m w : . PIPE MIN. PAVING MIN. BURIAL MIN. SELECT (� U <br /> B��W211, �0405-1�54�0 BAGKFILL: . STABILIZER BAR BY O Q <br /> (OR APPROVED SIZE CONDITION DEPTH (IN.) COVER (IN.) PLUG / LIQUID PORT, TYP. P MNFR. J O ILA <br /> COLOR / MNFR.) GRAVEL). . . Q U O <br /> . ., . ..; 311 UNPAVED 2,a 14 SENSOR, HOLDER, TYP. APPROVED LIQUID TUBING, TYPE � <br /> . .� 4" A.G. 13�� 9�� <br /> .• LIQUID-FILLED <br /> 411 COG pgL WALL F.R.P.F R P � <br /> o <br /> • DBL WALL, L <br /> a PIPING W/ VACUUM PP <br /> I CONTAINMENT <br /> P PE D SP GO E a ._...:...:.. .._ . . 4 UNPAVED 20 14 ..o <br /> • LLI <br /> — <br /> O ® O <br /> tY{�:• IN CONTAINMENT, - <br /> L4 <br /> . 4 A.G. 1411ha - - _-= SYSTEM BY BRAVO � <br /> _ =III-111=1 a SLOPE TO TANK <br /> 61 Z -111,h l-I I I a NATIVE 4 GONG. 11 <br /> -III 1 1,5110 CONC. FTG. SOIL LISTED FLEX CONNECTOR, TYP. r; <br /> m -I <br /> „ SEE MNFR. REQUIREMENTS FOR DIFF. MNFR. <br /> _III-I <br /> -11 ...,.:.-. <br /> I IN NTAINM NT <br /> PLUG G GO <br /> m <br /> P L PP E <br /> SUMP ENTRY / TERMINATION — — - —1 1BOTTOM OF ASSEMBLY, W/ BONDED - — — p SENSOR, HOLDER, TYP. <br /> TRENCH FIBERGLASS ALIGNMENT —� I j_ PEA GRAVEL BACKFILL �G�0�14 <br /> I;IIIIIIIIIIIIII1 III'1li III I z" / "� &" RINGS - - PER MNFR. RECS. _ W 0 � <br /> MIN., TYP. MIN. <br /> � �4 - Y <br /> INSTALL 8 TEST ALL EQUIPMENT Z A) W <br /> PER MNFR. REQUIREMENTS W W 0 U <br /> WV � u > w � <br /> W <br /> 6 FUEL ISLAND BOLLARD 3 SMITH RED THREAD IIA TRENCH DETAIL 1 UDC UNDER DISPENSER CONTAINMENT DETAILS Lu � w � <br /> SCALE. 1/2 = 1 -0 SCALE. 1/2 - I -0 (FOR 3 ,P PIPE) N.T.S. - SOME EXAGGERATION FOR CLARITY ♦ ♦ }- � �, •� <br /> VACUUM SENSOR NOSES SHOULD BE LONG ENOUGH SO V W Q r @ W <br /> THAT WHEN VACUUM SENSOR HOUSING IS REMOVED FROM m <br /> + 5 _�5��+ q�_4 �+ ITS MOUNT IT MAY BE EASILY SET ON THE TANK SLAB FOR <br /> EASE OF ANNUAL TESTING. TYPICAL FOR TANK SUMPS. cn (P <br /> �\----- -- 1 m d <br /> SUBMERGED TURBINE PUMP (S.T.P.) SEE SITE PLAN FOR SLAB THICKNESS, BURY DEPTH. Q <br /> MANIFOLD 455M5. W/ ELECTRONIC <br /> (N) CANOPY NEW II SQ LINE LEAK DETECTOR, SIPHON W.T. GOMPOSITE MANHOLE, � <br /> COLUMN BOLLARDS, CARTRIDGE AND EXT. SIPHON CHECK, H-20 RATED, MIN. Z <br /> / SH OUD � � TYP. W <br /> AS REQ'D1, V ., PER MNFR. INSTRUCTS. U <br /> Li MINI HYDROSTATIC SENSOR - <br /> W/IN FLUID RESERVOIR <br /> F171DISP. APPROVED FLEXIBLE TUBING ON FLUID FILLED, DBL. WALL CROWN SLAB AT <br /> I/4" HOSE BARB ADAPTER, CONTAINMENT SUMP MANWAY 1"/1' TYP <br /> ROUTE TO LIQUID/VACUUM <br /> SENSOR SUMP ENTRY / TERMINATION ASSEMBLY 4a.' <br /> W/ BONDED FIBERGLASS EXPLOSION PROOF "J" INTERSTITIAL FLUID TUBING <br /> PROVIDE 5io SLOPE AWAY <br /> 4�' x ,a" ALIGNMENT RINGS BOX W/ SEAL-OFFS, TYP.:..a. TO SUMP PORT N <br /> FROM DISPENSERS, 10 MAX. CLEAR,<LEVEIL o m Q <br /> W <br /> r <br /> AROUND DISP, TYP. AREA, �1 P. o ° W �t <br /> L'---------� FIrl :.. . . . . .: o0 00 0 48" (MIN) DBL. WALL FLUID- N <br /> � � W <br /> FILLED CONTAINMENT SUMP ( N [L <br /> NOTE: LAYOUT ASSUMES USE OF A 43.5" x 20.4" WIDE (BASE) o o <br /> DISPENSER, W/ CARDREADER RECESSED NO MORE THAN o PEA GRAVEL - ---� CONDUIT PENETRATION FITTING Z <br /> THE BASE. ADJUSTMENTS ARE APPROPRIATE e/OR BACKFILL, TYP, FOR DBL. WALL SUMPS, TYP. Q W <br /> REQ'D. FORA DIFFERENT CONFIGURATION. CONFIRM LISTED FLEX CONNECTOR SECONDARY CONTAINMENT �Q W O <br /> EQUIPMENT AND CANOPY LAYOUT BEFORE CONSTRUCTION. W/ SWIVEL(S) FIBERGLASS PIPE W/ FIBERGLASS VAC. / LIQUID SENSOR . -- - - - •.BALL VALVE Q U 0 O <br /> PRIMARY PIPE. SLOPE PIPE A MIN. ASSEMBLY, W/ VACUUM• ' <br /> FIBERGLASS THREADED 1/S" PER FOOT BACK TO THE FROM S.T.P. SIPHON, TYP. ' <br /> POINT-OF-SALE DEVICES & REACH RANGES - GBC 2022 EXCERPTS ADAPTER, SPIGOT x NPT MALE TANK SUMP. `JOIN SUMP BODY BASE AND <br /> CONCENTRIC REDUCER, CONNECTS APPROVED VAC. TUBING TEST PER MNFR. REQ'S., TYP. <br /> 118.305.3 SIZE. THE CLEAR FLOOR OR GROUND SPACE NOTE: SEAL FITTINGS W/ TO PRODUCT PIPING' <br /> 115-220.2 POINT-OF-SALE DEVICES. WHERE POINT-OF- SHALL BE 30 INCHES MINIMUM BY 45 INCHES MINIMUM. ADHESIVE/SEALANT COMPATIBLE THE SUMP ENTRY/TERMINATION FITTING <br /> SALE DEVICES ARE PROVIDED, ALL DEVICES AT EACH W/ PETROLEUM 4 METHANOL/ TO SECONDARY CONTAINMENT PIPE TEST PORT, TYP. 'APPR'D. VAG TUBING <br /> LOCATION SHALL COMPLY WITH SECTIONS 11B-7m7.3, 115-308.3 (SIDE REACH) UNOBSTRUCTED. WHERE A ETHANOL FUEL PRODUCTS AND FITTING <br /> 115-10112, AND 11B-�m�.9. CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL MATERIAL, PER MNFR. INSTRUCTIONS APPROVED FLEX --_ - <br /> CONNECTOR, TYP.' '• <br /> APPROACH TO AN ELEMENT AND THE SIDE REACH IS W (� O Z <br /> EXCEPTIONS: 1. WHERE A SINGLE POINT-OF-SALE - _ - � <br /> DEVICE IS INSTALLED FOR USE WITH ANY TYPE OF UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 ° ° J U } cYl <br /> INCHES MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 SENSOR HOLDER /� J U <br /> MOTOR FUEL, IT SHALL COMPLY WITH SECTIONS II5--10-1.2, INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. ..DBL. WALL F.R.P. PIPING W/ ♦ ♦ V Z O I1 6� <br /> 11B-1m7.3, 11B-1m-1.1.2, AND 118-70�.9. WHERE MORE THAN V lY Z <br /> VACUUM IN CONTAINMENT, d ONE POINT-OF-SALE DEVICE IS INSTALLED FOR USE WITH EXCEPTIONS: • . • . . � � :SLOPE TO TANK 1/8" PER FT.. Q Z J = U U � <br /> A SPECIFIC TYPE OF MOTOR FUEL, A MINIMUM OF TWO Q W U (� <br /> FOR THAT TYPE SHALL COMPLY WITH (SAME SECTIONS). INSTALLED SUMP BASE 4.. MIN., TYP. <br /> 1. AN OBSTRUCTION SHALL BE PERMITTED BETWEEN THE P I P E / SUMP PENETRATION TYPICAL COLLAR BY TANK MFR. .... o <br /> CLEAR FLOOR OR GROUND SPACE AND THE ELEMENT 7 —� <br /> 118.305.2 FLOOR OR GROUND SURFACES. FLOOR OR 4 BLACK IRON RISER, TYP. LL <br /> WHERE THE DEPTH OF THE OBSTRUCTION IS lm INCHES i i <br /> GROUND SURFACES OF A CLEAR FLOOR OR GROUND MAXIMUM. SCALE: 1/z = 1 -0 _� AUTO TANK GAUGE RISER Z <br /> SPACE SHALL COMPLY WITH SECTION 115-302. CHANGES 4x VENT / VAPOR <br /> IN LEVEL ARE NOT PERMITTED. 2. OPERABLE PARTS OF FUEL DISPENSERS SHALL BE EXTRACTOR ASSEMBLY TO F.R.P. PRODUCT PIPING <br /> PERMITTED TO BE 54 INCHES MAXIMUM MEASURED FROM <br /> EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE THE SURFACE OF THE VEHICULAR WAY WHERE FUEL ASSEMBLY <br /> PERMITTED. DISPENSERS ARE INSTALLED ON EXISTING CURBS, <br /> DOUBLE SWING JOINT ON VENT, 48" (MIN) DBL. WALL FLUID- <br /> FLEXIBLE CONNECTION, TYP, FILLED CONTAINMENT SUMP <br /> 7 ISLAND / DISPENSER LAYOUT _ (E) SUMP MONITOR HOUSING W/ ! DBL. WALL F.R.P. PIPING W/ <br /> SCALE: 1/4 = 1 Oil LIQUID SENSING PROBE ° VACUUM IN CONTAINMENT, MIN. <br /> o SLOPE TO TANK 1/8" PER FT., <br /> 2"4, VENT RISERS, TYP. VENT RACK SYSTEM - VAC. / LIQUID SENSOR ° TYP. - CONNECT VENT VACUUM <br /> MANIFOLD GASOLINE VENTS BY BRAVO ASSEMBLY, W/ VACUUM ° PORT ia SUP. SUMP, PLUG TEST <br /> AND INSTALL P/V VALVE, AS REQUIRED FROM S.T.P. PRIMARY - ° PORT ia OTHER TANK(S) } <br /> 12' MIN. ABOVE GRADE, TYP. SIPHON CHECK VALVE. <br /> VENT BOX SLAB, MOUNT 455M5. ON RISER MINI HYDROSTATIC SENSOR W <br /> PER BRAVO REQ'S. FOR ,' o W/IN FLUID RESERVOIR <br /> R6-500-VRC RACK W/ S.T.P. MANIFOLD 455M5. (RESERVOIR MAY BE SUMP <br /> \` W/ LINE LEAK DETECTOR - - J OPTION) <br /> MOUNT W/ LID ABOVE GRADE VEEDER-ROOT CCVP � o � W <br /> PER MNFR. REC'S. ° ° <br /> 4x VENT / VAPOR - - - - <br /> o EXTRACTOR Q <br /> a ASSEMBLY o ° ° AUTO. TANK GAUGE W/ GAP KIT <br /> MINI HYDRO. SENSOR, TYP. <br /> W/IN LIQUID RESERVOIR <br /> ATMOSPHERIC MANOMETER, <br /> APPROVED LIQUID TUBING W/ APPR'D. LIQUID TUBING, ° `� BALL VALVE, TYP. w w <br /> TYPICAL r o o w i-w iv <br /> CARD READER, PVC DRAIN, I MIN. INTO �. a a �, a ° CONDUIT / SUMP PENETRATION w ui <br /> KEYPAD PEA GRAVEL, TYP. r APPR'D. FLEX CONNECTORS --- \ ° FITTING, TYP. � o u w u <br /> - DBL. WALL, LIQUID-FILLED �uJ Liu a o n IT <br /> VENT CONTAINMENT a ° ° �, = cv <br /> ❑� SENSOR HOLDER, TYP. r r .I APPR'D. VAC TUBING DBL. WALL F.R.P. PIPING W/ � u 0 <br /> C1 SYSTEM BY BRAVO W z o w o <br /> (k ° r ° VACUUM IN CONTAINMENT, J [o m,� Q <br /> o r.i. ° ° - U <br /> d VAPOR PIPING PLUG TEST _ J W O� w <br /> Q DBL. WALL F.R.P. VENT - - _ , , � �� � <br /> A AV ACKFI <br /> - - PE GR EL B LL <br /> W <br /> X 0, ,OOC PIPING W/ VACUUM SUMP ENTRY / TERMINATION ° ° PORT a SUP. TANK (SHOWN), F- W Q o= n <br /> Q U U _ PER MNFR. REC S. .. N w z w <br /> W U O IN CONTAINMENT, ° ° ASSEMBLY W/ BONDED F.R.P. ° ° CONNECT REG. TANK 30 <br /> o o <br /> m m SLOPE TO TANK LISTED FLEX CONNECTOR, ALIGNMENT RINGS, TYP. W 4 _ z LL <br /> i=7 W <br /> Lu L PRODUCT SELECT TYP. _ DBL. WALL F.R.P. PRODUCT PIPING W/ - INSTALL TEST ALL EQUIPMENT z n`�Q o <br /> SUMP ENTRY / TERMINATION _ _ _ ���� IFRO l4 VACUUM IN CONTAINMENT, PER MNFR. REQUIREMENTS y z Q a O <br /> O ASSEMBLY, W/ BONDED MANIFOLD PIPING - SLOPE TO TANK 1/8" PER FT., MIN. Q u w u z U <br /> FIBERGLASS ALIGNMENT CONTAINMENT / VACUUM ). u, �n o <br /> RINGS - 0w�vanu <br /> wff!wwo <br /> FINISH GRADE INSTALL 8 TEST ALL EQUIPMENT PER MNFR. REQUIREMENTS INSTALL 4 TEST ALL EQUIPMENT PER MNFR. REQUIREMENTS u <br /> (8-ro00... SHOWN, 8-500... SIMILAR) (5-11... SHOWN, 8-500... SIMILAR)\— p�Q ] o <br /> SENSOR HOLDER <br /> DISPENSER ELEVATION VENT PIPING / RISER TRANSITION DETAILS U.S.T. TURBINE SUMP DETAILS ��v ARc <br /> C n ELF <br /> 8 SCALE: 1/2 = 1'-0'' N.T.S. - SOME EXAGGERATION FOR CLARITY 2 SCALE: 1" = 1'-0" (WITH SOME EXAGGERATION FOR CLARITY) VA <br /> PET = 4 <br /> �;1 NO.C2 84 ti <br /> REN.3-31-25 <br /> OF 9 'PET' SHEETS <br />