COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GROUSE RUN
>
4901
>
3600 - Recreational Health Program
>
PR0360251
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/29/2024 1:46:34 PM
Creation date
10/29/2024 1:45:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0360251
PE
3612 - PUBLIC POOL/SPA - ADDITIONAL
FACILITY_ID
FA0002673
FACILITY_NAME
QUAILBROOK COA
STREET_NUMBER
4901
STREET_NAME
GROUSE RUN
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11227018
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\jcastaneda
Supplemental fields
Site Address
4901 GROUSE RUN DR STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name and Address: QUAILBROOK COA, 4901 GROUSE RUN DR, STOCKTON 95207 <br />Swimming Pool Official Inspection Report <br /> #4 Safety Equipment <br />OBSERVATIONS: The body hook and life ring were inside the equipment enclosure. Ensure body hook and life ring are <br />available when spa is open. This was corrected on site. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br />This is (Minor - Food) Violation. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: One handrail was observed loose. Tighten handrail within three days . (REPEAT) <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a <br />point above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) <br />Pool operator shall keep ladders and handrails well maintained. (CCR 65535) <br />This is (Minor - Food) Violation. <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />Combined chlorine:ppm <br />85 <br />>8 <br />0 <br />0 <br />60 <br />NOTES <br />Spa <br />Close spa unit the corrections are made and verified by this department. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />LYDIA BAKER <br />, <br />(209) 616-3046Phone:EH Specialist: <br />Name and Title:Received by: , <br />Page 2 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0360251 08/06/2024 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.