Laserfiche WebLink
Environmental Health Department <br />Telephone: (209) 951-4391 Owner/Operator: PATMON COMPANY INC <br />Inspection Type: Routine Inspection <br />Address: 2506 COUNTRY CLUB BLVD, STOCKTON 95204 <br />Date: 08/08/2024Name of Facility:IRON HORSE APARTMENTS <br />Reinspection on or after: <br />Swimming Pool Official Inspection Report <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public <br />health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />VIOLATIONS AND CORRECTIVE ACTIONS <br /> #37 Electrical Hazards <br />OBSERVATIONS: The light inside the pool does not turn off when the ground fault circuit interrupter (GFCI) is tested. Repair <br />GFCI so that it is in good working order today. Close pool area until the corrections are made and verified by this department. <br />(REPEAT) <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply <br />with California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a <br />ground fault circuit interrupter. (CBC 3160B) <br />This is (Major) Violation. <br />MAJOR <br /> #4 Safety Equipment <br />OBSERVATIONS: The life ring lacks a throw rope and the body pole is not at least 12 feet long. Provide a rope and a 12 foot <br />minimum fixed length body pole today. (REPEAT) <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br />This is (Minor - Food) Violation. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The first step at the deep end ladder is cracked and broken. Repair/replace step today. (REPEAT) <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a <br />point above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) <br />Pool operator shall keep ladders and handrails well maintained. (CCR 65535) <br />This is (Minor - Food) Violation. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0360339 08/08/2024 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD