Laserfiche WebLink
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />October 30, 2024 <br /> Facility Address: <br /> 1176 STANISLAUS ST, ESCALON <br /> Facility Name: <br /> ESCALON UNIFIED SCHOOL DIST <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />CORRECTIVE ACTION: Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be <br />regularly tested to ensure proper operation. Immediately conduct all necessary testing of all liquid level sensing <br />devices to ensure proper operation, submit test results to the EHD. <br />This is a repeat violation (Class 2) Violation. <br />Code of Fed Regulations 112.8(d)(1) 4030027 - Buried piping is corrosion protected with protective wrapping, coating, <br />or cathodic protection. <br />OBSERVATION: The SPCC Plan failed to discuss buried piping with protective wrapping or coating, and to ensure it is <br />cathodically protected or otherwise satisfies corrosion protection standards for piping. <br />REGULATION GUIDANCE: (d)(1) Provide buried piping that is installed or replaced on or after August 16, 2002, with <br />protective wrapping and coating. You must also cathodically protect such buried piping installations or otherwise <br />satisfy the corrosion protection standards for piping in part 280 of this chapter or a State program approved under part <br />281 of this chapter. If a section of the buried line is exposed for any reason, you must carefully inspect it for <br />deterioration. If you find corrosion damage, you must undertake additional examination and corrective action, as <br />indicated by the magnitude of the damage. <br />CORRECTIVE ACTION: Immediately provide the buried piping installed or replaced on or after August 16, 2002, with a <br />protective wrapping and coating and cathodic protection. Provide proof of correction to the EHD. <br />This is a repeat violation (Class 2) Violation. <br /> 66 <br />CA Health and Safety Code 25270.6(a) 4010032 - Tank Facility Statement or Business Plan has been submitted . <br />OBSERVATION: A complete tank facility statement or a business plan has not been submitted . <br />REGULATION GUIDANCE: (a)(1) On or before January 1, annually, each owner or operator of a tank facility subject to <br />this chapter shall file with the statewide information management system, a tank facility statement that shall identify <br />the name and address of the tank facility, a contact person for the tank facility, the total storage capacity of the tank <br />facility, and the location and contents of each petroleum storage tank that exceeds 10,000 gallons in storage <br />capacity. A copy of a statement submitted previously pursuant to this section may be submitted in lieu of a new tank <br />facility statement if no new or used storage tanks have been added to the facility or if no significant modifications have <br />been made. For purposes of this section, a significant modification includes, but is not limited to, altering existing <br />storage tanks or changing spill prevention or containment methods. (2) Notwithstanding paragraph (1), an owner or <br />operator of a tank facility that submits a business plan, as defined in subdivision (d) of Section 25501 , to the <br />statewide information management system and that complies with Sections 25503 , 25505 , 25505.1 , 25507 , <br />25507.2 , 25508 , 25508.1 , and 25508.2 , satisfies the requirement in paragraph (1) to file a tank facility statement. <br />CORRECTIVE ACTION: This was corrected on site. A CERS submittal was made during the inspection today <br />referencing the HMBP in lieu of submitting a Tank Facility Statement . <br />This is (Class 2) Violation. <br /> 74 <br />Code of Fed Regulations 112.20(e) 4010044 - Substantial Harm Criteria certification maintained at the facility as <br />required. <br />OBSERVATION: The facility failed to complete and maintain (at the facility) the Substantial Harm Criteria certification <br />form. <br /> 78 <br />FA0003822 PR0528253 SC001 10/30/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 9 of 11 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD