Laserfiche WebLink
QUI/y <br /> SANsd0AQUIN Environmental Health Department <br /> COUNTY Jasjit Kang, REHS, Director <br /> Greatness grows here. Muniappa Naidu, REHS, Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco, REHS, RDI <br /> Willy Ng, REHS <br /> Steven Shih, REHS <br /> Elena Manzo, REHS <br /> Natalia Subbotnikova, REHS <br /> November 5, 2024 <br /> GREG MCGAA <br /> PO BOX 2057 <br /> LODI, CA 95240 <br /> RE: Well Pump Inspection <br /> Well Location: 11425 Bendorf Rd,Acampo Permit#: AP2401109 Inspection Date: 11-05-2024 <br /> The Environmental Health Department recently conducted a water well pump inspection at the above address <br /> and found the following issues at the time of the inspection. In order to protect the ground water supply and <br /> your water source from potential degradation, please take the associated corrective actions. <br /> X Lack of or Inadequate Concrete Platform around Wellhead. <br /> (SJC Water Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Extend concrete platform around the wellhead that extends two feet in all <br /> directions from the well casing. <br /> ❑ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code,Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑ Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. Inspector unable to take water sample <br /> due to missing sample tap. <br /> ❑ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> If you have any questions, contact: Naseem Ahmed, Senior Registered Environmental Health Specialist. <br /> Please call or send photo— (209) 616-3018 when work is complete. <br /> Icy Steven Shih, REHS <br /> Program Coordinator <br /> Cc: Moormans Water System Inc, 2120 Wilcox Rd, Stockton CA, 95205 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />