Laserfiche WebLink
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />May 13, 2024 <br /> Facility Address: <br /> 13401 S Union RD, MANTECA <br /> Facility Name: <br /> EDWARD CARDOZA <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 721 □ V □ R □ COSFailed to provide corrosion protection for buried pipingCFR 112.8(d)(1) <br /> 722 □ V □ R □ COSFailed to cap/blank-flange connection at transfer point and mark its origin if not in serviceCFR 112.8(d)(2) <br /> 723 □ V □ R □ COSFailed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contractionCFR 112.8(d)(3) <br /> 724 □ V □ R □ COSFailed to regularly inspect aboveground valves, piping, and appurtenancesCFR 112.8(d)(4) <br /> 725 □ V □ R □ COSFailed to conduct integrity and leak testing on buried piping any time it is worked onCFR 112.8(d)(4) <br /> 726 □ V □ R □ COSFailed to adequately warn vehicles entering facility to protect piping and other transfer operationsCFR 112.8(d)(5) <br /> 727 □ V □ R □ COSPlan failed to adequately describe overfill prevention methods for each containerCFR 112.7(a)(1), <br />112.8(c)(8) <br />Other Violations <br /> 4010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 4020 □ V □ R □ COSUnlisted Training violation See below <br /> 4030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 4040 □ V □ R □ COSUnlisted Release/Leaks/Spills violation See below <br /> 4050 □ V □ R □ COSUnlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 102 CFR 112.3, 112.6 Failed to prepare a written SPCC Plan in accordance with CFR Part 112. <br />OBSERVATION: This facility has an Aboveground Petroleum Storage Act (APSA) regulated shell capacity of 10,000 <br />gallons, and a Spill Prevention, Control, and Countermeasure (SPCC) Plan was not prepared. <br />REGULATION GUIDANCE: All facilities which have an APSA regulated shell capacity of 1,320 gallons or greater <br />shall prepare a written SPCC Plan which meets all of the requirements of the 40 CFR Part 112. This plan shall be <br />certified by a professional engineer in accordance with 40 CFR 112.3(d). <br />CORRECTIVE ACTION: Immediately prepare and implement an SPCC Plan in accordance with 40 CFR Part 112, <br />which includes all aboveground petroleum storage containers 55 gallons or larger. A copy of this plan shall be <br />maintained on-site, as required. Submit a copy of the SPCC Plan to the EHD for review; this copy will be returned to <br />the facility after it has been reviewed by the EHD. The facility has an option to submit a Tier II SPCC Plan or conduct <br />daily inspections to qualify for SPCC exemption. <br />This is a Class II violation. <br />FA0016754 PR0539051 SC001 05/13/2024 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 4 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD