Laserfiche WebLink
mos w F7avorivi r,or <br />'swim sem <br />NE' ird <br />1111E111111111 <br />tgarit <br />NWrion, <br />A <br />MI MINI ..p. <br />P I <br />wriAs <br />SK. Handholds (2-9018) <br />3. Other types of handholds permitted at spa. <br />SL. Permanent Markings (2-9014) <br />2. Min. of 2 depth markers indicating max. depth. <br />SN. Decks (2-9018) <br /> <br />1. Min. 4 ft. deck around 50% of spa and at spa steps. Min. 6 ft. deck separation between pool <br />and spa. No partial deck. <br /> <br />5. Unpaved areas (Landscape planters, etc.) must be min. 4 ft. away from spa. <br />SS. Spa Equipment (2-9031) <br />1. Two spas may share systems if flow and chlorination rates adjustable <br />SY. Signs and Safety Equipment (2-9025 and T22-65539) <br />1. Spa surface area sq.ft. divided by 10 equals <br />requires 4 in. letters. <br />"No Life Guard" sign is not required. <br />Body hook is not required. <br />Life ring is not required. <br />12. Spa "CAUTION" sign is required - posted near entrance <br />SZ. Spa Pool Special Requirements (2-9043 and 3-680-13) <br />Aeration/jet system separate from filtration system <br />Emergency shut-off switch for filter and jet pumps, <br />separation from jet timer. <br />for each spa. <br />(occupant load)(max. of 25). Sign <br />to spa. <br />and not connected to any pool. <br />labelled and adjacent to spa. Ten ft. <br />All items on page completed <br />Y. Signs and Safety Equipment (2-9025,T22-65539 and 65547) <br />Pool surface area ' sq.ft. divided by 20 equals 52- (Occupant Load, 4 in. letters). <br />"No Diving Allowed" signs (2 or more) in 4 in. letters for pools less than 6 ft. deep. <br />"No Lifeguard" warning in 4 in. letters and children under 14 notice. <br />Artificial Respiration illustration and notice to begin artificial respiration if needed. <br />Emergency phone numbers for nearest ambulance, fire, and police. <br />"No use allowed after dark" sign in 4 in. letters if no pool lighting. <br />"Danger: Gaseous Oxidizer-Chlorine" sign 4 in. letters. <br />Emergency evacuation procedure if gas chlorine is used. <br />Body hook bolted to a light, strong, non-telescoping 12 ft. pole. <br />Life ring, 17 in. dia., with 3/16 in. line to span width of pool. <br />first aid kit. <br />All items on page completed <br />, <br />, M r -• M L <br />M <br />LA M <br />111:11PMV "MI <br />MEW All <br />IMMIX1111 MEMdran <br />MINVAVAPL' <br />111111111611O <br />SAN JOAQUIN PUBLIC HEALTH SERVICES ENVIRONMENTAL HEALTH SWIMMING POOL PROGRAM <br />1601 East Hazelton Ave., P.O. Box 2009, Stockton, CA 95201, (209) 468-3420 <br />SPA POOL SUPPLEMENT TO SWIMMING POOL PLAN CHECK SHEETS <br />SA. Spa Construction (2-9003 and 9011) <br />1. Plans for the spa shall be drawn to a scale of 1 in. to 1 ft. <br />finish color may be white or light pastel color. A contrasting color is required on edges <br />of bench and steps. <br />Max. water depth over bench is 24 in. <br />max surface area 250 sq.ft.: max. depth 4 ft. <br />SC. Inlets (2-9042) <br />1. Spa may have 1 inlet and it need not be 18 in. below water level. <br />SF. Water Supply (2-9035) <br />1. Spas are exempt from having permanently installed line. <br />SG. Spa Bottom Drain (2-9042) <br />Duplicate drains for both the recirculation and aeration/jet systems or single drains <br />with safety covers for both systems. <br />SJ. Spa Steps (2-9015) <br />Tread min. 12 in. <br />One handrail for 9 in. max. riser, 2 handrails for up to 12 in. max. riser. <br />Handrail over steps and max. of 12 in. from plane of bottom riser.