My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
640
>
2300 - Underground Storage Tank Program
>
PR0537924
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2026 12:54:22 PM
Creation date
1/2/2025 11:17:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0537924
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0021892
FACILITY_NAME
Winters Gateway
STREET_NUMBER
640
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95304
APN
25025012
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
640 E ELEVENTH ST TRACY 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) T-1 87 T-2 91 T-3 DIESEL <br /> Are both vent and tank riser piping ® Yes ® Yes ® Yes ® Yes <br /> secondarily contained? ® No ® No ® No El No <br /> OPE Model 71SO 71SO 71SO <br /> What is the OPE response when ® Shut off ® Shut off ® Shut off L7 Shut off <br /> activated? Flow Flow Flow Flow <br /> (Check all that apply.) ® Restricts ®Restricts ® Restricts ® Restricts <br /> Flow Flow Flow Flow <br /> ® Audible ® Audible ® Audible ® Audible <br /> Alarm Alarm Alarm Alarm <br /> © Visual © Visual ® Visual ® Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping Yes* ® Yes* ® Yes* ® Yes* <br /> that may interfere with the OPE operation? ® No ® No ® No ® No <br /> At what level in the tank is the OPE set to 106.750 107.25 106.750 <br /> activate? Inches from bottom of tank <br /> What is the percent capacity of the tank at 9398% 94.31% 93.98% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to ® Yes ® Yes* ® Yes* ® Yes* <br /> respond when the stored substance © No ® No ® No ® No <br /> reaches the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results © Pass 0 Pass © Pass ® Pass <br /> ® Fail ® Fail Fail ® Fail <br /> S. COMMENTS <br /> Describe all answers marked "No"or"Fail"and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> * Mark here if: <br /> ® Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.