T-2 91 Appendix B <br /> 71 SO OverfiII Valve in Tank Shut off level Worksheet <br /> Important: This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- <br /> tion(AHJ)and review local,state,and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your region,as well as take into account other considerations such as extreme tank tilt. <br /> Take the following measurements with the valve in- <br /> stalled in the tank: <br /> Distance from the 71 SO inlet tube flange to the cast <br /> lug in the 71 SO body(see figures),upper tube length. <br /> Note: the Upper Tube Length must be at least 16"to in- <br /> clude the protective bend in the tube. <br /> (D) 55.75 <br /> Distance from the 71 SO inlet tube flange to the top and <br /> bottom of lower tube,valve length. <br /> (°) <br /> M= 163 <br /> Upper I <br /> V — <br /> 161 Tube <br /> Distance from the 71 SO inlet tube flange to the bottom <br /> of the tank. Note:If a tank bottom protector is present it <br /> may be necessary to add this thickness to dimension <br /> (OPW 6111 &61TP models add 0.6") (W)Valve <br /> (B)= 165 j Length, <br /> it <br /> bottom of <br /> From the tank calibration chart provided by tank manu- cut <br /> facturer find the dipstick number(Y)which corresponds <br /> to the 100%volume. (B) <br /> (Y)= 8010 �T To Tank <br /> (Y) <br /> 1. To determine shut-off percentage: Tanis <br /> Subtract upper tube length(D)from distance to tank (U)Valve Chart <br /> bottom (B) Length. 100% <br /> (X)=(B)—(D)-2"= 107.25 top of cut Volume <br /> Dipstick <br /> Using the tank calibration chart provided by the tank --' <br /> manufacturer determine the tank capacity at the cal- ?jl <br /> culated(X)dimension and the 100%volume(Y)tank <br /> capacity. fj <br /> (X)tank capacity In gallons= 7554 <br /> (Y)tank capacity in gallons= 8010 <br /> SO%=(X)capacity 1(Y)capacity x100= 94.3 <br /> Note: The overfill valve must be installed per ANJ require- <br /> ments and all applicable local,state,and national codes. If <br /> the overfill valve is set above the allowable shut-off percent- <br /> age the overfill valve must be removed and replaced. For <br /> reference 40 CFR part 280 Subpart B Section 280.20 overfill <br /> valves should beset to a maximum of 95%. <br /> 21 <br /> Downloaded From www.Manualslib.com manuals seat-cli engine <br />