Laserfiche WebLink
The following is an itemized list of CP22- UST FULL violations that have not <br /> been addressed for YRC INC (now Estes-Tracy) as of June 10, 2025. <br /> Open violations from February 26,2025 inspection <br /> Violation#2-2010010-Complete and accurate UST Operating Permit Application has been submitted.. <br /> OBSERVATION: UST Tank Information forms are not current in the California Environmental Reporting System <br /> (CERS). <br /> -The used oil tank(CERS ID10181485-002, map tank#2)lists that there is not a containment sump for the spill <br /> bucket.The spill bucket was observed in a containment sump on site. <br /> REGULATION GUIDANCE:Any change of information must be updated in CERS within 30 days of the changes. <br /> CORRECTIVE ACTION: Immediately tog into CERS, update the required information,and submit for review by the <br /> END. <br /> I3 This violation was corrected ❑This violation will be corrected by(date): <br /> © Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Corrections were made on CERS. <br /> Violation#52-2030036-Overfill prevention system has not been overridden and meets overfill <br /> requirements(TCR 9b). <br /> OBSERVATION:The following tanks do not have approved overfill methods installed.All have flappers(overfill <br /> prevention valves)installed but flappers are not an approved method for the tanks due to the tank contents. Most <br /> flappers have a manufacturer-specific minimum flow rate necessary for the device to properly operate.The contents of <br /> these tanks and the nature of how they are filed do not allow for a strong enough flow rate to shut off the valve. <br /> -CERS tank 1D 10181485-001 (map tank#7)containing soap. Has single-walled vent piping and direct bury spill <br /> container. <br /> -CERS tank 1D 10181485-002(map tank#2)containing used oil. Has single-walled vent piping and spill container in a <br /> sump.The input of used oil into this tank is not from the fill pipe with the spill bucket but rather connected from the <br /> shop in a different building, per technicians on site. <br /> -CERS tank ID 10181485-003(map tank#6)containing used oil. Has single-walled vent piping and direct bury spill <br /> container. <br /> -CERS tank ID 10181485-007(map tank#1)containing waste diesel. Has single-walled vent piping and direct bury <br /> spill container.This tank does not have waste diesel inputted via the spill bucket but is used as an overflow tank to <br /> catch overflows from the AST, per technicians on site. <br /> REGULATION GUIDANCE:All underground storage tanks shall be equipped with an overfill prevention system that <br /> does not allow for manual override and meets one of the following requirements: 1. Alert the transfer operator when <br /> the tank is 90 percent full by restricting the flow into the tank or triggering an audible and visual alarm; or 2_ Restrict <br /> delivery of flow to the tank at least 30 minutes before the tank overfills, provided the restriction occurs when the tank is <br /> filled to no more than 95 percent of capacity; and activate an audible alarm at least five minutes before the tank <br /> overfills;or 3. Provide positive shut-off of flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity; or, 4. Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the tank <br /> are exposed to product due to overfilling. <br /> Page 1 of 3 <br />