My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2026 9:20:44 PM
Creation date
1/2/2025 4:51:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0232495
PE
2361 - UST FACILITY
FACILITY_ID
FA0003854
FACILITY_NAME
ESTES - TRACY
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
21306046
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1535 E Pescadero AVE Tracy 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) Tank 2 WO Tank 7 Soapa <br /> Are both vent and tank riser piping ❑ Yes ❑ Yes ❑ Yes ❑ Yes <br /> secondarily contained? 0 No 0 No ❑ No ❑ No <br /> OPE Model 71SO-4 71SO-4 <br /> What is the OPE response when activated? 0 Shut off Z Shut off ❑ Shut off ❑ Shut off <br /> (Check all that apply.) Flow Flow Flow Flow <br /> ❑Restricts ❑Restricts ❑Restricts ❑Restricts <br /> Flow Flow Flow Flow <br /> ❑ Audible ❑ Audible ❑ Audible ❑ Audible <br /> Alarm Alarm Alarm Alarm <br /> ❑ Visual ❑ Visual ❑ Visual ❑ Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping ❑ Yes* 0 Yes* ❑ Yes* ❑ Yes* <br /> that may interfere with the OPE operation? ® No ❑ No ❑ No ❑ No <br /> At what level in the tank is the OPE set to 41.875" 81.75" <br /> activate? (Inches from bottom of tank) <br /> What is the percent capacity of the tank at 93.09% 94.03% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to 0 Yes 0 Yes ❑ Yes ❑ Yes <br /> respond when the stored substance ❑ No ❑ No ❑ No ❑ No <br /> reaches the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results <br /> 0 Pass 0 Pass ❑ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> 8. COMMENTS <br /> Describe all results marked "Fail"and each proposed remedy. <br /> Post replacement inspection witnessed by Inspector C. Presto of San Joaquin DEH. <br /> Work done under permit#SR2400651. <br /> Flow restrictor is assumed to be in place, unable to verify at this time. a return inspection will be scheduled. <br /> * Mark here if: <br /> ❑ Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />