A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> H &S ENERGY PRODUCTS LLC#3081 6633 PACIFIC AVE STOCKTON January 23 2025 <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 8 CA Code of Regulations 2715(a)(1)(A), 2715(a)(2)2010016-"Underground Storage Tank Statement of Understanding <br /> and Compliance Form"submitted (TCR 10). <br /> OBSERVATION:The Underground Storage Tank Statement of Understanding and Compliance Form was not found in <br /> CERS. <br /> -6633 Pacific Avenue was not listed as a site covered by the submitted Statement of Understanding and Compliance. <br /> REGULATION GUIDANCE:This form must be uploaded to the California Environmental Reporting System (CERS). <br /> CORRECTIVE ACTION: This was corrected on site. No further follow up is required. <br /> This is a repeat violation (Class 2) Violation. <br /> 45 CA Code of Regulations 2636(f)(2)2030025-LLD on DW press piping monitors hrly, detects a 3.0 gph leak, and <br /> restricts/shuts off flow(TCR 9d). <br /> OBSERVATION:The 87S line leak detector failed to detect a leak when tested. <br /> REGULATION GUIDANCE:All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. <br /> CORRECTIVE ACTION: Immediately have a properly licensed, trained, and certified contractor repair or replace the <br /> failed leak detector and obtain a permit within one business day from the EHD, if needed. If the failed leak detector <br /> can't be replaced immediately, there is a possibility that the 87 S UST system may be red tagged to prevent fuel <br /> inputs. <br /> This is a repeat violation (Class 2) Violation. <br /> 68 CA Code of Regulations 2712(i), 2634(e)2030046-A current UST Response Plan has been submitted. <br /> OBSERVATION:An approved copy of the response plan was not available for inspection. <br /> -Page 1 was missing from the on-site copy. <br /> REGULATION GUIDANCE:A copy of this plan shall be accessible on site at all times. <br /> CORRECTIVE ACTION: This was corrected on site. No further follow up is required. <br /> This is (Minor)Violation. <br /> 77 CA Code of Regulations 2712(f)2030073- Facility has corrected cited violations within 30 days of receiving report. <br /> FA0003834 PR0231784 SCO01 01/23/2025 <br /> EHD Rev.12/06/2021 Page 5 of 6 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />