My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 9:28:53 PM
Creation date
1/14/2025 9:59:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231656
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
85 E LOUISE AVE LATHROP 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> S. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (ore OPE per column) e7-a 87-B 91 nSL <br /> Are both vent and tank riser piping �/ Yes �/ Yes Yes �/ Yes <br /> secondarily contained? No No No No <br /> OPE Model OPW 71SO DPW 71SO OPW 71SO OPW 71SO <br /> What is the OPE response when activated? 21 Shut off ZI Shut off Y/ Shut off ti/ Shut off <br /> (Check all that apply.) Flow Flow Flow Flow <br /> Restricts Restricts 7Restricts Restricts <br /> Flow Flow Flow Flow <br /> Audible Audible Audible Audible <br /> Alarm Alarm Alarm Alarm <br /> ❑Visual Visual Visual Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping Yes' Yes* Yes* Yes* <br /> that may interfere with the OPE operation? f No No No �/ No <br /> At what level in the tank is the OPE set to <br /> activate? (Inches from bottom of tank) 103.375" 103.75" 102.625" 103.125" <br /> What is the percent capacity of the tank at <br /> 92% 92% 92$ 92% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to Y/ Yes Yes �/ Yes r/ Yes <br /> respond when the stored substance No No No No <br /> reaches the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results f Pass E <br /> Pass ,/ Pass Pass <br /> Fail Fail Fail Fail <br /> 8. COMMENTS <br /> Describe all results marked "Fail"and each proposed remedy. <br /> * Mark here if: <br /> Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank charts), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.