My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
2771
>
2300 - Underground Storage Tank Program
>
PR0234251
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2026 2:22:27 PM
Creation date
1/14/2025 10:35:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0234251
PE
2361 - UST FACILITY
FACILITY_ID
FA0003508
FACILITY_NAME
TULARE FARMS LLLP
STREET_NUMBER
2771
Direction
E
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
17710025
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2771 E FRENCH CAMP RD MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CP26 - UST FULL Inspection Report <br />Date: <br />January 14, 2026 <br />Facility Address: <br />2771 E FRENCH CAMP RD, MANTECATULARE FARMS LLLP <br />Facility Name: <br />Environmental Health DepartmentAMENDED <br />1/14/2026 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item #Remarks <br />4 23 CCR 16 2613(a)(4) and (b), 2650(a), (c), and (e) 2011012 - Facility has submitted and maintains a monitoring site <br />plan <br />OBSERVATION: The current UST Monitoring Site Plan is not a scaled diagram <br />REGULATION GUIDANCE: 2650 (c) Owners or operators must submit a monitoring site plan for approval by the Unified <br />Program Agency. The monitoring site plan must include, but is not limited to, the following: (1) a scaled diagram <br />indicating the layout of the tank(s) and piping to the extent known, including containment sumps. (2) locations of all <br />release detection equipment; and (3) if applicable, each vacuum, pressure, or hydrostatic interstitial monitoring zone. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a (Minor) Violation. <br />5 23 CCR 16 2613(a)(6) and (b), 2650(a), (d), and (e) 2011013 - Facility has submitted a complete and accurate UST <br />Response Plan <br />OBSERVATION: An approved copy of the response plan was not available for inspection. <br />- The emergency contact information of the Responsible person Jann Janssen has not been provided. <br />REGULATION GUIDANCE: Owners or operators must submit a response plan to the Unified Program Agency which <br />demonstrates, to the satisfaction of the Unified Program Agency, that any unauthorized release will be removed from the <br />secondary containment as soon as practical. This must be within a time consistent with the ability of the secondary <br />containment to contain the hazardous substance but must not exceed 30 days. The response plan must include, but is <br />not limited to, the following: (1) A description of the proposed methods and equipment to be used for removing and <br />properly disposing of any hazardous substances, including the location and availability of the required equipment if not <br />permanently on site, and an equipment maintenance schedule for the equipment located on site. (2) For methods of <br />monitoring where the presence of the hazardous substance in the interstitial space cannot be determined directly, for <br />example, where liquid level measurements are used as the basis for determination, the response plan must specify the <br />proposed method(s) for determining the presence or absence of the hazardous substance if the indirect method indicates <br />a possible unauthorized release of hazardous substance. (3) The name(s), title(s) and emergency contact information of <br />the person(s) responsible for authorizing any work <br />necessary under the response plan or, if applicable, identify that there is a continuously staffed emergency operations <br />center authorized to coordinate such a response and provide a 24-hour phone number for that center. <br />CORRECTIVE ACTION: Submit a complete and accurate UST Response Plan. <br />This is a (Minor) Violation. <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 4 of 6EHD - CUPA Inspection Report IS03 <br />CP26 - UST FULL <br />1/14/2026FA0003508 PR0234251 4599628
The URL can be used to link to this page
Your browser does not support the video tag.