My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
420
>
2300 - Underground Storage Tank Program
>
PR0231906
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2026 7:47:40 PM
Creation date
1/16/2025 2:01:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231906
PE
2361 - UST FACILITY
FACILITY_ID
FA0003776
FACILITY_NAME
KWIK SERV LODI BW 113*
STREET_NUMBER
420
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06202042
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
420 W KETTLEMAN LN LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br /> _ r�Eor�.gcrioN O �v��f/p/7 a�°r9r 4ppe�d <br /> Underground Storage Tank 46 <br /> Monitoring Sy►stem Certification Form <br /> TANK GAUGING TESTING <br /> eck this box if tank gauging is used only for inventory control. <br /> ®deck this box if NO tank gauging equipment is installed. <br /> 0 00 not coin fete this section if either box is checked. Yes No NA <br /> AllVyirin9 has been. 1) visually inspected for kinks, breaks and proper entry and <br /> ie�mination, and 2 tested for round faults-,.here all in-tank gauging probes visually inspected for damage and residue buildup ❑ ❑ ❑ <br /> Ito ensure that floats move freely, functionally_tested, and confirmed o erational? �� ❑ ❑ <br /> Was;c of system's product level readings tested? <br /> Was accuracy of system's water level readings tested? �] ❑ ❑ <br /> Were all probes reinstalled properly? ❑ ❑ ❑ �" <br /> Were all items on the equipment manufacturer's maintenance checklist completed? ❑ ❑ ❑ <br /> Probe ID be Model ❑ <br /> Tanks Monitored Pass Fail <br /> CCOMMENTS — -- <br /> ❑ ❑ <br /> Describe all answers marked "No"or"Fail"and proposed remedy. <br /> List all monitoring equipment either� replaced or repaired.� DSL_/E-85 Split An p <br /> p Annular failed testing, need to return to replace and retest <br /> ' DSL. Leak detector failed testing, need to return to replace and retest <br /> tib <br /> 3f�/fie <br /> �q< <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.