Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> CQUNT AMENDED <br /> 5/20/2025 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SHERIFFS OPERATIONS CTR#1 7000 N MICHAEL CANLIS RD FRENCH CAMP January 03 2025 <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 10 CA Code of Regulations 2638(c), 2638(d)2030074-Annual Monitoring System Certification Form to the CUPA within <br /> 30 days of completion of the test. <br /> OBSERVATION:Annual monitoring system certification and leak detector testing was performed on 1/11/2024 and a <br /> test report was submitted on 2/15/2024,4 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed <br /> in a timely manner. <br /> This is a repeat violation (Class 2) Violation. <br /> 13 CA Code of Regulations 2637.1(d),2637.1(e)2010017- Spill bucket testing results submitted to the UPA within 30 <br /> days of testing. <br /> OBSERVATION:Annual spill container testing was performed on 1/11/2024 and a test report was submitted on <br /> 2/15/2024,4 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed <br /> in a timely manner. <br /> This is a repeat violation (Class 2) Violation. <br /> 24 CA Code of Regulations 2632(c), 2634(d),2636(f)2030003- Leak detection system maintains continuous monitoring <br /> that activates an audible and visual alarm. <br /> OBSERVATION: During the time of inspection,the dispensers were observed to be disconnected from the panel.The <br /> technician could not determine the connection problem.The audible and visual alarm were not tested to ensure <br /> continuous monitoring of the tank system. <br /> REGULATION GUIDANCE:All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: Correct immediately by having a properly licensed,trained, and certified contractor replace <br /> the failed component with a functional component(LG 113-x listed, if applicable), and obtain a permit within one <br /> business day from the EHD, if needed. If the failed component can't be replaced immediately,there is a possibility <br /> that the diesel and 87 UST system may be red tagged to prevent fuel inputs. <br /> FA0003787 PR0232437 SCO01 01/03/2025 <br /> EHD Rev.12/06/2021 Page 5 of 9 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />